3.10.2
Setting the required purging RPM
The MCTC material file calibration procedure can be used to determine a starting point for the purging
speed. When the material calibration has ended successfully, the last used speed is copied to the purging
speed parameter.
For more information about material files, r
efer to paragraph “Material files”
in the manual of the used unit.
3.10.3
Adjusting the purge motor speed
In case the color of the end product is not as required, the speed of the motor during purging can be
changed. The purge motor speed can be
adjusted from the “
Operator
menu”.
In multicomponent setups, make sure the right dosing unit is selected prior to entering the prime menu.
3.10.4
Purge recipe function
It is recommended to use the recipe function, the used purge speed can be stored to the recipe. For
multicomponent systems, the purge speed is saved for all components within the recipe.
Loading a recipe will also recall the purge speed stored to the selected recipe.
Changing the purge speed will activate the “save recipe indicator”, the recipe needs to be saved to save the
last made change for future use.