Using the purge function
Purge function type 1
Purging can be done before or during production by activating the purge mode:
1
Select the right recipe for the next production order (optional)
2
Go to the Operator menu
3
Press the Purge tab
4
Change the purge speed if required and press the purge button
5
Purge the Injection Molding Machine
6
When purging finished, press OK
7
Start production (only when production is not started yet)
Before starting the purge function, be sure the material hoppers of the components used during the purge
are sufficient filled with material. When purging is activated while the system is
“OFF”, the hopper loaders
will not be activated and no alarms will show.
When the purge mode is active, the MCTC will now wait for a start input signal or a purge signal. As soon the
one of the signals is activated, the dosing tool will rotate as long as the signal is active.
Then purge speed cannot be changed when purging is activated.
Purging will be activated for ALL components simultaneously within one group.
To deactivate a component in a multi component group, set the purge speed of the component to 0 RPM.
Purge function type 2
Purge function type 1 is also available when using purge function type 2.
This functionality requires service settings to be changed. Contact your distributor or Movacolor representative for more info.
Step by step instructions for the Operator
1
Select the right recipe for the next production order
2
Start production on the MCTC
3
Purge the Injection Molding Machine
4
Start production on the Injection Molding Machine
Before starting the purge function, be sure the material hoppers of the components used during the purge
are sufficient filled with material.
When purging is activated while the system is “OFF”, the hopper loaders
will not be activated and no alarms will show.
When during production status “STANDBY” INP
-3 is activated, the dosing motor will start running at purge
speed.
The motor will run at purge speed as long as INP-3 is activated or until the normal dosing start input is
activated.