38
MCTC manual
Active events
A list of all active events can be displayed by opening the event screen:
An event is active as long the root cause of the event has not been solved. A message pop up of an active
event will return every 60 seconds.
Operator events
Operator events can be shown by pressing:
All (production) settings changed by the operator are recorded and can be reviewed in this list. A maximum
of 50 events will be displayed in this list. More events are stored at the controller and can be downloaded by
using MCSmart PC application or the USB function.
Tooling login or higher required for recalling this list.
Alarm history
The warning/alarm event history list can be opened by pressing:
A list with warning/alarms that occurred will appear. A maximum of 50 events will be displayed. More events
are stored at the controller and can be downloaded by using MCSmart PC application or the USB function
(csv file). The alarm history can be cleared using the reset button, only when logged in as supervisor.
Tooling login or higher required for recalling this list.
Events
4.6.1
System events
These events apply to the whole system.
Code Event
Description
Default
501
AUX module error!
Cannot connect to AUX module
Warning
502
Invalid MCSmart Address Range
Wrong IP address for MCSmart server
Warning*
503
No MCSmart communication
Cannot connect to MCSmart server
Warning*
1001 Write failed!
Internal I
2
C write to memory failed
Alarm*
1002 Production settings error
Production parameters not set (correctly).
Alarm
1501 Product weight deviation!
LineControl output product weight is not within
deviation limits od set product weight.
Warning*
1502 Maximum puller speed!
LineControl maximum puller speed exceeded
Warning*
4.6.2
Group events
Group events can be set separately for each group in the system.
Code Event
Description
Default
2001 Main material empty!
Main hopper is empty
Off
2501 Extruder capacity deviation!
LineControl Extruder capacity deviation between set
and act capacity.
Warning*
2502 Minimum extruder speed!
LineControl Extruder speed below minimum
Warning*
2503 Maximum extruder speed!
LineControl Maximum extruder speed exceeded
Warning*