System
Main Material Sensor
The MCTC or MCBC can be provided with a Main Material Sensor. This
sensor can be used to detect a low material level in the main hopper.
5.1.1
Alarm settings
When a Main Material Sensor is used, the alarm (event 2001) for this
sensor needs to be set. Standard
, the event is configured “OFF”. (Refer to
chapter “Events” about how to setup events)
5.1.2
Electrical connections
The main material sensor has 4 wires: brown, blue, white and black. The black wire should not be connected.
The sensor needs to be connected to input 1 of the MCTC.
MCTC Terminal
Wire color
12
Blue
13
White
14
Brown