63
MCTC manual
8.8.3
Extrusion - gravimetric mode - relay
Production settings:
The following parameters can be seen in the production screen, depending on operation or settings:
The production data can be entered by touching the corresponding field
1.
Unit button:
To enter unit screen. Detailed production settings and parameters can be set and read
2.
Additive amount set point (%)
(dosing % can be set from this screen)
3.
Production status
4.
Extruder throughput set point(kg/h.)
5.
Recipe menu
6.
Prime:
Filling the dosing cylinder before start.
The prime menu appears by pressing . Settings (speed/time) can be changed. Press confirm to
start priming. Each unit must be primed separately, select the unit to prime before pressing the prime
button.
7.
Production (Motor On/Off)
Press
to start dosing. The motor on/off switch will turn from green to red when dosing is started.
The start LED blinks when the units are waiting for an input signal. If the units are dosing the start LED
lights continuously.
For stopping production press again. The motor on/off switch will turn to green again.
Please note that it is possible that the first dosing(s) are not sufficient, because of the cylinder filling with material. It takes some time to stabilize.
4
5
6
2
1
3
7