MTUX/IA-63-00 – Installation Manual
133
Date: 2017/02/17
00
17.4.1.2
Installation Advices
All installation advices are based on HIRD - SX - 0129x-01 (ITAS 832 SP),
please refer to the data sheet.
TX and RX is related to the respective device.
Standard ComPort on MT in Com3 on the MDR50 central connector.
Com Gnd 19 is to be connected to pin 26 -29 (MDR50)
On/Off Control activation pin (pin 6/grey in M12-8 ITAS) is to be connected
to pin 5 =
External Power Source: 8—32 VDC (5VDC optional¹)
Power Consumption: 1 Amp max transmit
65mA Standby
on/off signal line
Transient Protection: SAE J1113/11/12
Reverse Voltage Protection: 24V tested
Note: On/Off control through power-line results in a 30sec start-up
delay.
•
•
•
•
•
•