MTUX/IA-63-00 – Installation Manual
145
Date: 2017/02/17
00
19.3 COM Ports in MT-VisionAir X ETSO
Ports
Assignment to
COM 1
Signal from
TAS 600 series
Signal from FLARM
Signal from Garrecht TRX1090
Protocol in <TCAS> <TAS1SEL>:
– Avidyne/Ryan
– ZAON (no longer supported)
– FLARM
– Garrecht TRX1090
COM 2
GPS signal
Protocol in <AUX> <SETUP> <GPS>:
– Integral GPS
– Fast Integral GPS
– Trimble
– King KLN90
– Garmin 430/530
– Universal FMS
– FLARM
COM 3
(1)
Signal from FLARM
(only used, if FLARM is com-
bined with Avidyne/Ryan)
Protocol in <TCAS> <TAS2SEL>:
– FLARM and mtpro.ini
COM 3
(2)
Serial port for ITAS modul
Protocol set in mtpro.ini
COM 3
(3)
Serial port for Crossfill from
Garmin
no entry in mtpro.ini
Check possible conflict with TCAS
combined!
COM 4
Stormscope WX-500 / WX-670 Protocol set in mtpro.ini
Table 19.3: COM Ports assignment
NOTES
Technically COM ports 1–4 are equivalent.
In mtpro.ini the following is to be obtained:
– Modem = COM 0 is mandatory!
– Specification of COM port = 0 can be set
to several ports which are not in use.
Summary of Contents for MT-VisionAir X ETSO
Page 10: ...MTUX IA 63 00 Installation Manual 10 Date 2017 02 17 INTENTIONALLY LEFT BLANK ...
Page 12: ...MTUX IA 63 00 Installation Manual 12 Date 2017 02 17 INTENTIONALLY LEFT BLANK ...
Page 28: ...MTUX IA 63 00 Installation Manual 28 Date 2017 02 17 INTENTIONALLY LEFT BLANK ...
Page 107: ...MTUX IA 63 00 Installation Manual 107 Date 2017 02 1700 12 4 Dimensions in mm ...
Page 112: ...MTUX IA 63 00 Installation Manual 112 Date 2017 02 17 13 3 Dimensions in mm ...
Page 125: ...MTUX IA 63 00 Installation Manual 125 Date 2017 02 1700 INTENTIONALLY LEFT BLANK ...
Page 137: ...MTUX IA 63 00 Installation Manual 137 Date 2017 02 1700 ...
Page 138: ...MTUX IA 63 00 Installation Manual 138 Date 2017 02 17 ...
Page 139: ...MTUX IA 63 00 Installation Manual 139 Date 2017 02 1700 INTENTIONALLY LEFT BLANK ...
Page 146: ...MTUX IA 63 00 Installation Manual 146 Date 2017 02 17 INTENTIONALLY LEFT BLANK ...