AirWorks AWK-3131-RCC
Introduction
1-7
ATTENTION
When the system fails to boot, the LEDs for STATE (Green), FAULT, and WLAN will all light up
simultaneously and blink at one-second intervals. This may be due to improper operation or uncontrollable
issues, such as an unexpected shutdown while updating the firmware. To recover the firmware, refer to the
“Firmware Recovery” section in Chapter 6.
Beeper
The beeper emits two short beeps when the system is ready.
Reset Button
The RESET button is located on the top panel of the AWK-3131-RCC. You can reboot the AWK-3131-RCC or
reset it to factory default settings by pressing the RESET button with a pointed object such as an unfolded
paper clip.
•
System reboot: Hold the RESET button down for under 5 seconds and then release.
•
Reset to factory default: Hold the RESET button down for over 5 seconds until the STATE LED starts
blinking green. Release the button to reset the AWK-3131-RCC.
Relay (Digital Output)
The AWK-3131-RCC has one relay output consisting of the 2 terminal block contacts on the top panel, as shown
below. These relay contacts are used to forward system failures and user-configured events.
The two wires attached to the relay contacts form an open circuit when a user-configured event is triggered. If
a user-configured event does not occur, the relay circuit will remain closed. For safety reasons, the relay circuit
is kept open when the AWK-3131-RCC is not powered up.
Summary of the AWK-3131-RCC’s Relay Status
Power Status
Event
Relay
Off
–
Open
On
Yes
Open
No
Short
www.ipc2u.ru