AirWorks AWK-3131-RCC
Web Console Configuration
3-19
NOTE
Transmission power indicates the maximum value of transmission power which the user plans. However, the
real transmitted power depends on the radio module and some facts, such as country, regulatory limitations
and data rate. Please check the Transmission power in Status > Wireless Status for a real and updated value
of transmission power, which the AWK is currently using.
You can refer to the related glossaries in the reference section for detailed information about the
above-mentioned settings. By setting these parameters properly, you can better tune the performance of your
wireless network.
Noise protection
Setting
Description
Factory Default
Enable/Disable
Adjusts the interference coping capability of the wireless signal.
This option should be enabled for communication distance
under 500 meters, and should be disabled for communication
distances over 500 meters.
Enable
WMM
Setting
Description
Factory Default
Enable/Disable
WMM is a QoS standard for WLAN traffic. Voice and video data
will be given priority bandwidth when enabled with WMM
supported wireless clients.
Disable
Full 11a channel support
Setting
Description
Factory Default
Enable/Disable
“Full 11a channel support” allows users to select one channel
from 802.11a, including channels in licensed and unlicensed
bands.
Disable
ACC Connection Threshold
Setting
Description
Factory Default
ACC Connection
Threshold
If the signal strength of an AWK-3131-RCC can be above this
value for the period of time specified in the “ACC Connection
Time” field, this AWK-3131-RCC will be considered as a
connecting candidate.
-60dBm
ACC Disconnection Threshold
Setting
Description
Factory Default
ACC Disconnection
Threshold
If the signal strength of the AWK-3131-RCC is below this
threshold value for the period of time specified in the “ACC
Disconnection Time” field, the ACC link will be brought down.
-60dBm
ACC Connection Time
Setting
Description
Factory Default
ACC Connection
Time
This is the period of time for an AWK-3131-RCC to be
considered as a connecting candidate.
60 seconds
ACC Disconnection Time
Setting
Description
Factory Default
ACC Disconnection
Time
This is the period of time for an ACC link to be considered as a
poor connection. The ACC link will be brought down after the
specified time period.
60 seconds
Turbo Roaming (for Client mode only)
Setting
Description
Factory Default
Enable/ Disable
Moxa’s Turbo Roaming can enable rapid handover when the
AWK-3131-RCC, as a client, roams among a group of APs.
Disable
www.ipc2u.ru
www.moxa.pro