AWK-5222 User’s Manual
Other Console Configurations
3-40
Admin auth type
(for V1, V2c, V3, and V3 only)
Setting
Description
Factory Default
No Auth
Use
admin
account to access objects. No
authentication
MD5
Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.
SHA
Provides authentication based on
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.
No Auth
Admin private key
(for V1, V2c, V3, and V3 only)
Setting
Description
Factory Default
Disable
No data encryption
DES
DES-based data encryption
AES
AES-based data encryption
Disable
Private Key
A data encryption key is the minimum requirement for data encryption (maximum of 63
characters)
Private MIB Information Device Object ID
Also know as
OID
. This is the AWK-5222’s enterprise value. It is fixed.
Storm Protection
In general, one host should not be allowed to occupy unlimited bandwidth, particularly when the
device malfunctions. For example, so-called “broadcast storms” could be caused by an incorrectly
configured topology or a malfunctioning device.
Storm Protection
Setting
Description
Factory Default
Enable/Disable
Enable or disable Broadcast Storm
Protection globally for multicast packets
Enable
Multicast and flooding
Setting
Description
Factory Default
Enable/Disable
If you enable Storm Protection, the
Multicast and flooding option will show
up. You can Enable or Disable Broadcast
Storm Protection globally for unknown
multicast and unknown unicast packets.
Disable