Pin Number
Assignment
1
VCC
2
DATA-
3
DATA+
4
Ground
WARNING
To keep the EXPC-1319 within the IP66 rating’s waterproof specifications, when the
USB ports are not in use operators must replace the protective caps and the tethers,
and make sure they have been properly fastened. Please note that when reinstalling
the protective caps they must be tightened to 136 N-cm (12 in-lbs) to ensure the
unit is sealed to IP66 specifications.
In addition, because of the danger posed by the maximum 5V @ 500 mA power
supply of standard USB ports, care must be taken to protect the EXPC-1319 from
power accidents in damp environments. To guarantee safety from severe electrical
shoks or electrocution, in damp conditions users should disconnect the entire
computer from its power source before connecting or disconnecting any USB
devices.
You may refer to
Appendix B: Statement of Regulatory Approval
for the
technical details regarding regulation Class 1 Div. 2 devices.
Connecting Serial Devices
The EXPC-1319 comes with two RS-232/422/485 serial ports with DB9 male connector.
Step 1: Disassemble the waterproof DB9 connector
into four parts.
Step 2: Connect the serial signal wires with the correct
pin definition. See the following figure and table.
Step 3: When finished, assemble the DB connector
parts, and connect to the DB9 connector on the bottom
panel of the EXPC-1319. Make sure the connector has
been securely fastened to ensure the waterproof
function.
The pin assignments for RS-232/422/485 serial ports are shown in the following table:
DB-9 Male Port
RS-232/422/485 Pinouts
Pin
RS-232
RS-422
RS-485-4W RS-485-2W
1
DCD
TxDA(-)
TxDA(-)
–
2
RxD
TxDB(+)
TxDB(+)
–
3
TxD
RxDB(+)
RxDB(+)
DataB(+)
4
DTR
RxDA(-)
RxDA(-)
DataA(-)
5
GND
GND
GND
GND
6
DSR
–
–
–
7
RTS
–
–
–
8