41
Appendix A Pinouts and Cable Wiring
C114HI is suitable for RS-232, RS-422 or RS-485 communications. Each port can be
set to RS-232, RS-422 or RS-485 interface independently via the jumpers. Refer to
Chapter "Hardware Installation and IO-IRQ" for more details.
In data communications, the term
DTE
is Data Terminal Equipment like terminal or PC
COM1/2. The term
DCE
is Data Communication Equipment like modem. Their precise
pinouts and cable wiring are as follows.
The following comparison table is for EIA Standards RS-232, RS-422 and RS-485.
Mode of operation No. of Drv. No. of Rcv. Max. length ( FT ) Max. Rate ( bps )
RS-232
single ended
1
1
50
20K
RS-422
differential
1
10
4000
10M
RS-485
differential
32
32
4000
10M
A.1 RS-232
The following lists pinouts of the RS-232 port.
C114HI DB-9 Male Connector
C114HI Pin-head Connector
1
DCD
1
DCD
2
RxD
2
RxD
3
TxD
3
TxD
4
DTR
4
DTR
5
GND
5
GND
6
DSR
6
DSR
7
RTS
7
RTS
8
CTS
8
CTS
9
RI
9
RI
10
NC