2-2
Industio
CI-134 Series User’s Manual
l
Interface Selection Switch SW2 for Port 1/2/3/4:
ON *
Set the port interface to RS-485.
OFF
Set the port interface to RS-422.
l
Data Mode Selection Switch SW1 for Port 1/2/3/4:
(Valid if SW2 is ON)
ON *
Set the RS-485 port to Automatic Data Direction Control Mode.
OFF
Set the RS-485 port to By RTS Mode.
l
Termination Resistor Port 1/2/3/4 Jumper JP3/4/5/6: (
Valid if SW2 is ON)
Open *
Not using Termination Resistor
Shor t
Using Termination Resistor
In addition, it has the following default settings for I/O addresses and Interrupt
number:
I/O address:
0x180
(Port 1),
0x188
(Port 2),
0x190
(Port 3),
0x198
(Port 4)
IRQ:
10
INT Vector:
0x1C0
Note !
If the default settings above ar e what you desir ed and good for the
system without conflicts, you may simply install the boar d in the
system and go dir ectly to the next chapter , “Softwar e
Installation”. Other wise, follow the instr uctions below.
2.
After you set all the jumpers and switches, you should do either
the nor mal
har dwar e installation
(detailed in the later section, “Hardware Installation with
IO-IRQ Utility”) or
the quick har dwar e installation
(detailed right in the next
section, “Quick Hardware Installation”). The latter is provided to facilitate the
hardware installation, only under the circumstances that:
l
Only one
Industio
CI-134 Ser ies
boar d
is allowed to install in a system.
l
Windows NT and 95/98
are the only operating systems supported.
l
CAP J umper J P1 is shor t
and I/O address
0xA700
must be free.
Quick Hardware Installation
To fully utilize the superior feature of flexible hardware configuration design of the
Industio
CI-134 Series, a quick and easy method of installation is designed, which
absolutely saves you from hardware configuration effort, i.e.,
installation
WITHOUT r unning configur ation pr ogr am: Io-ir q.exe
.
Simply always shor t the