3-30
Smartio
CP-168U User’s Manual
2.
Click on the desired CP-168U board, and then click on [
Properties
].
3.
Select the [
Ports Configuration
] tab, click on the specific port, and then click on the
[
Port Setting
] button.
4.
Check the
Auto Enumerating COM Name
check-box to assign continuous COM
numbers for subsequent ports. For example, if COM3 is assigned to Port 1, then COM4
will be automatically assigned to Port 2.
5.
Select an Rx FIFO Trigger from the Rx FIFO Level pull-down list. Rx FIFO trigger
levels from High to Low are available, with a default value is High Level (120 bytes).
Check
Set the change to all ports
check-box to apply the just defined Rx FIFO
Trigger to all ports.
6.
Select a Tx FIFO Size from the Tx FIFO Level pull-down list. Tx FIFO Level from
High to Low are available, with a default value is High Level (128 bytes). Check
Set