- 8 -
ATTENTION
Before connecting the TN-5524-8PoEto the power input, make
sure the power source voltage is stable.
Connecting the Relay Outputs
Each TN-5524-8PoE switch has two sets of relay outputs—relay output 1
and relay output 2.The M12 A-coded 5-pin male connector on the
TN-5524-8PoE’s front panel is used for the two relay outputs. Use a power
cord with an M12 A-coded 5-pin female connector to connect the relay
contacts. You can purchase an M12 power cable from Moxa; the model
number is CBL-M12 (FF5P)/OPEN-100 IP67.
Pinouts for the relay output port on TN-5524-8PoE
FAULT:
The two sets of relay contacts of the M12 A-coded 5-pin male connector
are used to detect user-configured events. The two wires attached to the
fault contacts form an open circuit when a user-configured event is
triggered. If a user-configured event does not occur, the fault circuit
remains closed.
Connecting the Data Lines
10/100BaseT(X) Ethernet Port Connection
All TN-5524-8PoE models have 24 10/100BaseT(X) Ethernet ports (4-pin
shielded M12 connector with D coding). The 10/100TX ports located on
the TN-5524-8PoEfront panel are used to connect to Ethernet-enabled
devices. Most users configure these ports for Auto MDI/MDI-X mode, in
which case the port’s pinouts are adjusted automatically depending on
the type of Ethernet cable used (straight-through or cross-over), and the
type of device (NIC-type or HUB/Switch-type) connected to the port.
In what follows, we give pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports. We also give cable wiring diagrams for
straight-through and cross-over Ethernet cables.
Pinouts for the 10/100BaseT(X) Ports on the TN-5524-8PoE