background image

- 12 - 

Installing the SD Card 

The UC-5100 Series computers come with a socket for storage 
expansion that allows users to install an SD card. 
 
Follow these steps to install the SD card: 

1.

 

Unfasten the screw and remove 
the panel cover. 
The SD socket is located on the 
front panel of the computer. 

 

2.

 

Insert the SD card into the 
socket. Ensure that the card is 
inserted in the right direction. 

3.

 

Replace the cover and fasten the 
screw on the cover to secure the 
cover. 

To remove the SD card, simply push 
the card in and release it. 

Adjusting the CAN DIP Switch 

The UC-5111 and UC-5112 computers come with one CAN DIP switch 
for users to adjust the CAN termination resistor parameters. To set up 
the DIP switch, do the following: 
 

1.

 

Find the DIP switch location on the 
top panel of the computer 

2.

 

Adjust the setting as required. The 

ON value is 120Ω, and the default 

value is OFF.

 

 

Adjusting the Serial Port DIP Switch 

The UC-5100 computers come with a DIP switch for users to adjust the 
pull-up/pull-down resistors for the serial port parameters. The serial 
port DIP switch is located on the bottom panel of the computer. 
 
Adjust the setting as required. The ON setting corresponds to 

1KΩ

 and 

the OFF setting corresponds to 150KΩ. The 

default setting is OFF. 

 

Each port consists of 4 pins; you must switch all 4 pins of a port 
simultaneously to adjust the value of the port. 

Summary of Contents for UC-5100 Series

Page 1: ...ericas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2018 Moxa Inc All rights reserved ...

Page 2: ...computing platform with 4 serial ports 2 Ethernet ports SD socket mini PCIe socket 2 CAN ports 4 DI 4 DO 10 to 60 C operating temperature range UC 5101 T LX Industrial computing platform with 4 serial ports 2 Ethernet ports SD socket 4 DI 4 DO 40 to 85 C operating temperature range UC 5102 T LX Industrial computing platform with 4 serial ports 2 Ethernet ports SD socket mini PCIe socket 4 DI 4 DO ...

Page 3: ... 3 NOTE The console cable and power jack can be found beneath the molded pulp cushioning inside the product box Appearance UC 5101 UC 5102 ...

Page 4: ...ice is functioning normally Off Power is off Ready Yellow OS has been successfully enabled and the device is ready Ethernet Green Steady On 10 Mbps Ethernet link Blinking Data transmission is in progress Yellow Steady On 100 Mbps Ethernet link Blinking Data transmission is in progress Off Transmission speed below 10 Mbps or the cable is not connected ...

Page 5: ...an be used to reset the operating system back to the factory default status Press and hold the Reset to Default button between 7 to 9 seconds to reset the computer to the factory default settings When the reset button is held down the Ready LED will blink once every second The Ready LED will become steady when you hold the button continuously for 7 to 9 seconds Release the button within this perio...

Page 6: ...ible current in each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment This equipment is intended to be supplied by a certified External Power Supply the output of which meets SELV and LPS regulations Temperature Caution B...

Page 7: ...viewing boot up messages or for debugging system boot up issues PIN Signal 1 2 3 GND 4 TxD 5 RxD 6 7 8 Connecting to the Network The Ethernet ports are located on the front panel of the UC 5100 The pin assignments for the Ethernet port are shown in the following figure If you are using your own cable make sure that the pin assignments on the Ethernet cable connector match the pin assignments on th...

Page 8: ...uts The DI DO connectors are located on the top panel of the computer Refer to the adjacent diagram for the pin definitions The DI DO wiring diagram is given below Connecting to a CAN Device The UC 5111 and UC 5112 are provided with 2 CAN ports allowing users to connect to a CAN device The pin location and assignments are shown in the following table PIN Signal 1 CAN_H 2 CAN_L 3 CAN_GND 4 5 6 7 CA...

Page 9: ...t panel to remove the cover and find the location of the socket The cellular module package includes 1 cellular module and 2 screws The cellular antennas should be purchased separately to fit your installation requirements Follow these steps to install the cellular module 1 Set the antenna cables aside for convenience of installation and clear the wireless module socket as shown in the figure ...

Page 10: ...the cover and secure it using two screws 5 Connect the cellular antennas to the connectors Antenna connectors are located on the front panel of the computer The Wi Fi module package includes 1 Wi Fi module and 2 screws The antenna adapters and Wi Fi antennas should be purchased separately to fit your installation requirements Follow these steps to install a Wi Fi module 1 Set the antenna cables as...

Page 11: ...e computer 6 Connect the Wi Fi antennas to the antenna adapters Installing Micro SIM Cards You will need to install a Micro SIM card on your UC 5100 computer Follow these steps to install the Micro SIM card 1 Remove the screw on the cover located on the front panel of the UC 5100 2 Insert the Micro SIM card into the socket Make sure you place the card in the right direction To remove the Micro SIM...

Page 12: ...omputers come with one CAN DIP switch for users to adjust the CAN termination resistor parameters To set up the DIP switch do the following 1 Find the DIP switch location on the top panel of the computer 2 Adjust the setting as required The ON value is 120Ω and the default value is OFF Adjusting the Serial Port DIP Switch The UC 5100 computers come with a DIP switch for users to adjust the pull up...

Reviews: