33
POSSIBLE ALARMS AND SOLUTIONS:
ALARM DESCRIPTION
SYMPTOM(S)
MOST COMMON
SOLUTION(S)
Dirty Filter Alarm High
Frequency
•
Dirty Filters
Change
all
Filters, then press
“Clear Alarm”
Dirty Filter Alarm High
Pressure
•
Dirty Filters
Change
all
Filters, then press
“Clear Alarm”
Drive Alarm
•
Loose Connection
•
Motor Tapped
Incorrectly
Cycle Power
If alarm persists, contact
MP
SYSTEMS
Low Flow Alarm
•
Clogged Inlet
•
Sucking Air
•
Min Current setting
too high
Prime Feed Pump
Check Tank Fluid Level
Check Inlet for Blockages
Then press “Clear Alarm”
Pressure Sensor Alarm
•
Pressure Sensor
Unplugged
•
Damaged Pressure
Sensor
Connect or Replace Sensor,
then press “Clear Alarm”
Tank Overflow Alarm
•
Restricted Return
Hose
•
Improper hose routing
•
Thick Fluid
Check Return Hose, then
press “Clear Alarm”
If alarm persists, contact
MP
SYSTEMS