This command sets the operational mode of the power supply: rotary, keypad, external, or remote.
Keypad configuration is not available for XR Series power supplies.
Command Syntax:
[CONFigure]:SETPT <NR1>
Parameters:
0 = ROTARY, 1 = KEYPAD, 2 = EXTERNAL, 3 = REMOTE
Examples: CONF:SETPT
0
SETPT 0
Query Syntax:
[CONFigure]:SETPT?
Returned Parameters: <NR1>
Related Commands: None
4.3.11 GPIB Communications Subsystem
4.3.11.1 GPIB:VERS? (Optional GPIB only)
This query reads the firmware version of the GPIB communication module.
Command Syntax:
none
Query Syntax:
[SYSTem][:COMMunicate]:GPIB:VERSion?
Parameters: none
Examples: SYST:COMM:GPIB:VERS?
GPIB:VERS?
Returned Parameters: <Firmware Ver. XX.Y>
Related Commands: None
4.3.11.2 GPIB:ADDR (Optional GPIB only)
This command sets the address of the GPIB module of the power supply. The address can be 1 to
30 where address 0 is normally assigned to the GPIB Master. The factory default address is 1.
Command Syntax:
[SYSTem][:COMMunicate]:GPIB:ADDRess <NR1>
Parameters: 1-30
Examples: SYST:COMM:GPIB:ADDR
27
GPIB:ADDR 27
65
Summary of Contents for XR III series
Page 1: ...OPERATING AND SERVICE MANUAL XR SERIES III DC POWER SUPPLIES...
Page 2: ......
Page 3: ...MAGNA POWER ELECTRONICS INC 39 ROYAL ROAD FLEMINGTON NJ 08822 February 20 2012...
Page 4: ......
Page 88: ...Figure 4 1 Status Byte Generation Figure 4 2 ESE and ESR Generation 76...
Page 95: ...IEEE Standard CLS ESR ESE STB SRE IDN SAV RCL RST Notes 1 C command Q query 83...
Page 97: ...Figure 5 1 Configuration setup Figure 5 2 GPIB communications setup 85...
Page 99: ...Figure 5 4 Virtual Control Panel Figure 5 5 Command Panel 87...
Page 102: ...Figure 5 7 Calibration Panel Figure 5 8 Firmware Panel 90...
Page 103: ...Figure 5 9 Modulation Panel 91...
Page 123: ...Figure B 1 Information Panel Figure B 2 Configure Panel 111...
Page 124: ...Figure B 3 Reboot in Progress Panel Figure B 4 Web Control Panel 112...