Fault Messages
197
EMC NOT FOUND
PWR OFF PRINTER
Insert Cartridge
Yes
The printer does not
contain an EMC and
the firmware attempted
to access the EMC.
Install EMC or contact your
authorized customer service
representative.
ENTER to Stop
Yes
Normal message when
a test print pattern that
will run continuously
has been enabled.
Press the
↵
(ENTER) key to
stop printing the test pattern.
ERROR: DC PROGRAM
NOT VALID
Yes/No
The printer cannot find
the data controller
program or the
validation checksum is
corrupt.
Power off the printer for 15
seconds, then power back
on. If the problem persists,
contact your authorized
customer service
representative.
ERROR: FLASH
DID NOT PROGRAM
Yes/No
The printer
encountered an error
trying to program flash
memory.
Power off the printer for 15
seconds, then power back
on. If the problem persists,
contact your authorized
customer service
representative.
ERROR: INSUFFICIENT
DRAM
Cycle Power
Yes/No
Not enough RAM
memory available for a
printer function.
1.
Power off the printer for
15 seconds, then power
back on again.
2.
If the message
reappears, delete files
from FFS as they are
copied into RAM.
3.
Select the Optimize &
Reboot menu option.
4.
If the message
reappears, replace the
controller PCBA. Write
down the message and
return it with the
defective board.
Table 15. Fault Messages
Displayed Message
Can User
Correct?
Explanation
Solution