MEDIA SETUP Submenus
85
Set Label Length
This feature selects whether the Sensed Distance value derived from an Auto
or Manual Calibrate will be used to set the Label Length value in the MEDIA
SETUP menu.
•
Manual
(factory default). The Sensed Distance value derived from an
Auto or Manual Calibrate
will not
override
or change the Label Length
value.
•
Automatic
. When an Auto or Manual Calibrate is performed, the Sensed
Distance value derived from either calibrate
will override
and change the
Label Length value. If no Auto or Manual Calibrate is performed, the
current Label Length value will be used.
NOTE:
When Set Label Length = Automatic and Gap/Mark Sensor = Gap,
the printer will subtract the Gap Length value (in the SENSOR
SETUP menu) from the Sensed Distance value obtained when the
Auto or Manual Calibrate was performed.
If you set the label length to Automatic, the Enable setting for Use
Label Length under the Sensor Setup menu will be ignored.
TOF Detect Fault
Allows selection of three different TOF (Top-of-Form) detection faults.
NOTE:
The correct Label Length value, equal to the physical length of the
installed label, must be entered MEDIA SETUP menu.
•
3 Labels
(factory default). The printer displays a Gap Not Detected fault
and stops printing when media has advanced a distance equal to three or
more times the Label Length value set in menu.
•
9 Labels
•
1 Label