13
GB
CLEANING AND MAINTENANCE
ATTENTION! Unplug the device from the mains before cleaning and maintenance. Do not immerse the
humidifier base in water or any other liquid.
ATTENTION! Do not use aggressive cleaning agents, solvents, petroleum products, etc. for cleaning.
ATTENTION! After detaching the water tank, pour out the remaining water in the base of the device by tilting
it slightly over a sink.
1.
Clean the outer surface of the base using a damp cloth and then wipe it dry.
2.
Clean the water tank at least once a week. Fill it half with water and a mild cleaning agent,
screw down the plug and shake the tank with both hands. After finishing cleaning, pour the
water out of the tank and rinse it thoroughly. Clean the outer wall of the tank with a damp
cloth.
3.
Regularly remove scale from the ultrasound transducer as necessary. Moisten a soft cloth
with a mixture of vinegar and water and hold it for several minutes gently against the trans-
ducer (3) and the surfaces on which the scale has accumulated. After finishing scale removal,
clean the surfaces with a cloth moisten with water. Be careful not to cause any mechanical
damage to the transducer while cleaning it.
4.
At least once a week, rinse the air filter (11) and ceramic filter (8) with running water, and dry
thoroughly. Regular cleaning of the filters helps maintain high performance of the device. To
access the air filter (11), remove the cover (12) in the bottom of the base (1). Refit the filters
after cleaning. Exchange the ceramic filter once a year, and the air filter when it has been
mechanically damaged.
5.
The remote control is powered by a 3 V CR2025 battery. To access the
battery, press the lock tab (arrow A in fig. 2) and pull out the battery
case (arrow B in fig. 2). Observe correct polarity when installing the
battery.
ATTENTION! Do not dispose of spent batteries with household waste. Dispose
of spent batteries at designated battery collection points or return them to the
seller. Do not dispose of batteries in fire.
6.
If you anticipate a break in the operation of the humidifier, drain all
water from it. Never expose the device to direct sunlight.
A
B
fig. 2