Model Number RL01SH

 

Air Pressure Booster System • Installation and Operating Instructions

Midwest Pressure Systems, Inc.

RAV

Rev. 0

MPS

M I DW E ST
PRESSURE
SY S T E M S

MPS

M I D W E S T
PRESSURE
S YS TE M S

MPS

M I D W E S T
PRESSURE
SY S T E M S

MPS

M I D W E S T
PRESSURE
SY S T E M S

MPS

M ID WE ST

PR ESSURE
SYS T E MS

MPS

M I DW E ST
PRESSURE
SYS T E M S

MPS Logos

12/5/91

1/2" Square

3/4" Square

1" Square

1-1/4" Square

1-1/2" Square

2" Square

MPS

M ID WE ST

PR ESSURE
SYS T E MS

Mount the Model RL01SH air pressure booster system on a 
horizontal surface. Other mounting orientations are not 
recommended.   The booster system vibrates while operating. 
Use the four 9/32” mounting holes shown in the diagram to the 
right, to bolt it to a solid surface.

1

Connect your shop air line to the 1/4” FNPT air inlet filter on the 
front of the booster.  A shutoff valve can be installed upstream of 
the filter for convenient removal of the system for maintenance. 
The booster has a built-in discharge pressure regulator. Do not 
install a supply pressure regulator. Lowering the supply pressure 
reduces the efficiency of the system. The unit is permanently 
lubricated.  

Use of an inlet lubricator will void the 

warranty. The maximum inlet pressure is 150 psig.

2

Attach discharge line to the 1/4” FNPT port on the side of the 
receiver tank.  

If the application requires a lubricator, 

make sure the lubricator is installed downstream of 
the booster.

 A filter should be installed to protect 

downstream components from seal/booster wear particles. 

3

The discharge pressure regulator is set by the black, snap-
lock knob mounted on the top of the unit. Pull up on the knob 
to unlock it. Adjust the knob by turning it clockwise for a 
higher discharge pressure or counterclockwise for a lower 
discharge pressure. The upper gauge indicates the inlet 
pressure. The lower gauge indicates the discharge pressure. 
Supply shop air to the booster and it will start to operate. Set 
the regulator to attain the desired discharge pressure, and 
push down on the regulator knob until it “clicks” to lock the 
regulator on that setting. The regulator is self-relieving. When 
the discharge pressure setting on the regulator is reduced, the 
higher pressure stored in the system will vent through the 
regulator until pressure equilibrium is reached. 

If the inlet 

pressure is higher than 140 psig, it is possible to 
set the regulator so the booster exceeds the 
maximum discharge pressure of 280 psig. Do not 
operate the booster under these conditions. It is 
designed to operate continuously at a maximum 
discharge pressure of 280 psig.

5

The air pressure booster system will operate as long as there is 
demand for high pressure air. When there is no demand, the 
booster will “stall” at the pressure set by the discharge regulator. 
The stalled condition consumes no energy and does not damage 
the booster. The booster will start up automatically when the 
pressure falls slightly as a result of demand for high pressure air.

7

Mounting Bolt Pattern:

 12.0” 

3.0” 

The accumulator tank has a 1/4” ball valve to drain condensate. A 
drain line or automatic drain valve can be attached to this valve if 
needed. Close the valve before starting booster.

4

The accumulator is rated for 300 psig and includes a relief valve 
set for 300 psig to prevent operation of the booster above its 
maximum allowable discharge pressure of 280 psig. 

8

For more precise booster control, set the discharge regulator for 
a higher pressure than required, and install a filter and secondary 
regulator on the discharge line of the accumulator. This allows 
for greater accumulator storage capacity, and minimizes pressure 
fluctuations in the system. For maximum high pressure air 
storage, air pressure booster systems are set to charge the 
accumulator to the maximum pressure of two times the supply, 
and the secondary regulator in the discharge line of the 
accumulator is set at the desired, lower pressure. Make sure that 
any downstream components are rated for the accumulator 
pressure, or are protected by a relief valve in case the secondary 
regulator fails.

6

Drain Valve
1/4” FNPT

Inlet port
1/4” FNPT

300 psig
Pressure
Relief Valve

Discharge
port
1/4” FNPT

Midwest Pressure Systems, Inc.

850 Transport Drive, Valparaiso, IN 46383
Phone 219-462-0070  Fax 219-318-2277

www.midwestpressuresystems.com