DCA20SPXU2D 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (03/25/11) — PAGE 21
OUTPUT TERMINAL PANEL FAMILIARIZATION
OUTPUT TERMINAL PANEL
The Output Terminal Panel (Figure 7) shown below is
located on the right-hand side (left from control panel) of
the generator. Lift up on the cover to gain access to
receptacles and terminal lugs.
NOTICE
Terminal legs “O” and “Ground” are considered bonded
grounds.
OUTPUT TERMINAL FAMILIARIZATION
The “Output Terminal Panel ” (Figure 7) is provided with
the following:
Two 120/240V output receptacles @ 50 amp
Two Circuit Breakers @ 50 amps
Two 120V GFCI receptacles @ 20 amp
Two GFCI Circuit Breakers @ 20 amps
Four Output Terminal Lugs (U, O, V, and Ground)
AUX. POWER RECEPTACLES
120/240V, 50 AMPS
120 VAC, 20 AMP
GFCI RECEPTACLES
Y
X
W
CS-6369
TWIST-LOCK
CIRCUIT BREAKERS
FOR GFCI RECEPTACLES
RECEPTACLE
AND
CIRCUIT BREAKER
PANEL
MQ
POW
ER
ACCESS DOOR
LIFT TO OPEN
HARD WIRE
HOOKUP PANEL
U
O
V
BLACK
RED
WHITE
GREEN
SINGLE PHASE
240 -120 VAC
OUTPUT TERMINALS
NEUTRAL
TERMINAL
GROUND
TERMINAL
CIRCUIT BREAKERS
FOR CS-6369 TWIST
LOCK RECEPTACLES
Figure 7. Output Terminal Panel
Summary of Contents for DCA20SPXU2
Page 48: ...PAGE 48 DCA20SPXU2D 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 1 03 25 11 GENERATOR ASSY...
Page 50: ...PAGE 50 DCA20SPXU2D 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 1 03 25 11 CONTROL BOX ASSY...
Page 58: ...PAGE 58 DCA20SPXU2D 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 1 03 25 11 BATTERY ASSY...
Page 60: ...PAGE 60 DCA20SPXU2D 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 1 03 25 11 MUFFLER ASSY...
Page 62: ...PAGE 62 DCA20SPXU2D 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 1 03 25 11 FUEL TANK ASSY...
Page 64: ...PAGE 64 DCA20SPXU2D 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 1 03 25 11 ENCLOSURE ASSY...
Page 73: ...DCA20SPXU2D 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 1 03 25 11 PAGE 73 NOTES...