DCA-150SSJU — PARTS AND OPERATION MANUAL — REV. #3 (09/07/01) — PAGE 29
DCA-150SSJU — CONTROL PANEL
The definitions below describe the controls and functions of
the DCA-150SSJU "
Control Panel
" (Figure 8).
1.
Main Circuit Breaker –
This three-pole, 400 amp main
breaker is provided to protect the UVW voltage output
terminals from overload.
2.
AC Ammeter –
Indicates the amount of current the
load is drawing from the generator.
3.
Ammeter Change-Over Switch –
This switch allows
the AC ammeter to indicate the current flowing to the
load connected to any phase of the output terminals, or
to be switched off.
4.
Voltmeter Change-Over Switch –
This switch allows
the AC Voltmeter to indicate phase to phase voltage
between any two phases of the output terminals, or to
be switched off.
5.
Voltage Regulator Control –
Allows adjustment of the
generator’s output voltage.
6.
Frequency Meter –
Indicates the output frequency in
hertz (Hz). Normally 63Hz. with a calibration difference
of +0.5% with the mechanical governor or +0.25% with
the electronic governor.
7.
AC Voltmeter –
Indicates the single phase output
voltage present at the UVW terminals.