DCA-150SSJU — PARTS AND OPERATION MANUAL — REV. #3 (09/07/01) — PAGE 55
ENGINE SHUTDOWN (Key)
To shutdown the generator, use the following procedure:
1. Switch both the MAIN, GFCI and LOAD circuit breakers
(Figure 75) to the “OFF” position.
2. Set the engine throttle lever to the idle (low) position.
3. Let the engine cool by running it for 3-5 minutes with no
load applied.
4. Turn the starter switch to “STOP” position (Figure 76).
5. Remove the load from the UVW terminal strip.
Figure 75. Main, GFCI and Load
circuit breakers
DCA-150SSJU — SHUTDOWN PROCEDURE
Figure 79. Engine Controller
Status LED (OFF)
Figure 78. Off/Manual Auto Switch (OFF)
5. Verify that the "Engine Running" status LED (Figure 79)
on the Auto/On/Offf Engine Controller display is "OFF"
(not lit).
4. Place the Off/Manual/Auto Switch (Figure 78) in the "
OFF/
RESET
" position.
ENGINE SHUTDOWN (Engine Controller)
To shutdown the generator, use the following procedure:
1. Switch both the MAIN, GFCI and LOAD circuit breakers
(Figure 77) to the “OFF” position.
2. Set the engine idle to (low) position.
3. Let the engine cool by running it for 3-5 minutes with no
load applied.
Figure 77. Main, GFCI and Load
circuit breakers
6. Remove the load from the UVW terminal strip.
Figure 76. Starter Switch (Stop
Position)
Summary of Contents for DCA-150SSJU
Page 2: ...PAGE 2 DCA 150SSJU PARTS AND OPERATION MANUAL REV 3 09 07 01 ...
Page 22: ...PAGE 22 DCA 150SSJU PARTS AND OPERATION MANUAL REV 3 09 07 01 DCA 150SSJU GENERATOR DECALS ...
Page 25: ...DCA 150SSJU PARTS AND OPERATION MANUAL REV 3 09 07 01 PAGE 25 NOTE PAGE ...
Page 99: ...DCA 150SSJU PARTS AND OPERATION MANUAL REV 3 09 07 01 PAGE 99 NOTE PAGE ...