DCA1100SSC 60 HZ GENERATOR • OPERATION MANUAL — REV. #1 (01/17/18) — PAGE 13
SPECIFICATIONS
Table 1. Generator Specifications
Model
DCA1100SSC
Type
Revolving field, self ventilated,
open protected type synchronous generator
Armature Connection
Star with Neutral
Phase
3
Standby Output
968 kW (1,210 kVA)
Prime Output
880 kW (1,100 kVA)
Voltage - 3 Ø
440, 460 and 480V Reconnectable
Frequency
60 Hz
Speed
1800 rpm
Power Factor
0.8
Aux. AC Power
Single Phase, 60 Hz
Aux. Voltage/Output
4.8 Kw (2.4 kW x 2)
Dry Weight
28,880 lbs. (13,100 kg.)
Wet Weight
35,000 lbs. (15,873 kg.)
Table 2. Engine Specifications
Model
CUMMINS QST30-G5, Tier 2 Certified
Type
4 cycle, watercooled, direct injection, turbocharged
charged air cooled
No. of Cylinders
12 cylinders
Bore x Stroke
5.51 in. x 6.49 in. (140 mm x 165 mm)
Displacement
1,860 cu. in. (30,480 cc)
Rated Output
1350 HP @ 180 rpm
Starting
Electric
Coolant Capacity
55.7 gal. (211 liters)
Lube Oil Capacity
40.7 gal. (154 liters)
Lube Oil Type
#2 Diesel Fuel
Fuel Type
API Service Class CI-4
Fuel Tank Capacity
211 gal. (570 liters)
Fuel Consumption
62.6 gal. (237 L)/hr at
full load
46.5 gal. (176 L)/hr at
75% load
33.0 gal. (125 L)/hr at
50% load
18.3 gal. (69.3 L)/hr at
25% load
Battery
12V 200Ah x 4 (24V System)