background image

500kW Containerized

Diesel Generator Set

Model

Emissions

Standby Rating

Prime Rating

EGC-500C

EPA Certified

60 Hertz

500kW (625kVA)

450kW (562.5kVA)

Standard Features

Cummins Heavy Duty Diesel Engine

„

4-cycle design, turbocharged, aftercooled, direct injection

„

Polymide blade cooling fan

„

Engine coolant heater

„

Meets  EPA Tier 2 emissions standards

Fuel System

„

800 gallon, single wall fuel tank

„

Fuel priming system

„

Fuel/water separators and drip pan

„

Electric fuel run pump

„

External fuel fill

„

30 micron Racor

®

 fuel filter system

Alternator

„

Brushless, 4-pole, synchronous, WYE connection

„

Class H insulation system conforms to NEMA MG1-22, BS5000,
CSA-C22-2, IEC-34-1 standards for temperature rise

„

Drip-proof, self-venting, amortisseur windings

„

Epoxy impregnated windings with tropical insulation for increased
environmental protection and long life

Electronic Voltage Regulator

„

Electronic automatic voltage regulator provides precise regulation

„

Separate three-phase excitation for fast recovery from block loads
and motor starting

Full Load Acceptance

„

Accepts 100% of standby nameplate rating in one step, in compliance
with NFPA, para 5-13.2.6

Generator Control Panel

„

Basler vibration-isolated controller

„

Manual or remote engine start/stop

„

RS485/Modbus communication support

„

Safety shutdowns

„

Externally mounted emergency stop switch

„

Generator mainline circuit breaker, 100% rated, electronically
operated, UL listed

Specially Designed Container

„

20 ft. ISO container, sound-attenuated, foam-lined for extremely quiet
operation

„

Solidly mounted battery rack and cooling system

„

Intregral vibration isolators

„

Exterior polyurethane coating system provides long life in extreme
operating conditions

„

Interior DC lights and timer switch

„

Crankcase filtration system

„

Critical grade silencer with heat blankets

Warranty

„

Engine-generator sets are covered by an express written, one-year
limited warranty

(Shown with optional ISO trailer chassis)

EGC500C  Rev 0

Summary of Contents for EGC-500C

Page 1: ...ulator Electronic automatic voltage regulator provides precise regulation Separate three phase excitation for fast recovery from block loads and motor starting Full Load Acceptance Accepts100 ofstandbynameplateratinginonestep incompliance with NFPA para 5 13 2 6 Generator Control Panel Basler vibration isolated controller Manual or remote engine start stop RS485 Modbus communication support Safety...

Page 2: ...r Cleaner Type All Models Dry Dual Element Engine Electrical System Battery Charging Alternator Ground Type Negative Volts 24 VDC Ampere Rating 70A Starter Motor Rated Voltage 24 VDC Minimum Recommended Battery for 0 C Cold Cranking Performance 1425 Ah Alternator Specifications Make Marathon Magna Max Type 4 Pole Rotating Field Number of Leads 10 or 12 Generator Type Rotating Field PMG Voltage Reg...

Page 3: ...ne RPM Engine run time Generator voltage Generator current Generator frequency Oil pressure Battery voltage Fuel level measurements Running Hour Meter Coolant temperature Generator under over voltage alarm shutdown Generator under over frequency alarm shutdown Over Current alarm shutdown Warm up and cooling functions Maintenance timer Digital Controller Features Cooling System Exhaust Manifold Typ...

Page 4: ...s approximate Wet weight does not include fuel Generator Set Genset to Genset Paralleling Control System Base Load to Utility Paralleling Control System Custom Outlet Panels Rotary Voltage Selector Switch High Wye Low Wye Voltages Auxiliary Oil Reservoir with Level Control 10 gallon Centrifugal Oil Filter System Oil Pan Heater with Thermostat Alternator Strip Heater AC Battery Charger with Shore P...

Reviews: