DCA-15SPX3 GENERATOR — PARTS & OPERATION MANUAL — REV. #2 (09/03/01) — PAGE 35
DCA-15SPX3 — PRE-SETUP
Battery Cable Installation
ALWAYS
be sure the battery cables (Figure 15) are properly
connected to the battery terminals as shown below. The RED
RED
RED
RED
RED
cable is connected to the positive terminal of the battery,
and the
BLACK
cable is connected to the negative terminal
of the battery.
CAUTION :
When connecting battery do the following:
1.
DO NOT
connect the battery cables to the battery
terminals when the key is in the ignition and is set in
'START' mode. ALWAYS remove the key from the
ignition and the ignition switch is in the OFF position
when connecting the battery.
2. Place a small amount of grease around both battery
terminals. This will ensure a good connection and will
help prevent corrosion around the battery terminals.
CAUTION :
Inadequate battery connections may
cause poor starting of the generator, and
create other malfunctions.
Wiring
Inspect the entire generator for bad or worn electrical wiring
or connections. If any wiring or connections are exposed
(insulation missing) replace wiring immediately.
Piping and Hose Connection
Inspect all piping, oil hose, and fuel hose connections for
wear and tightness. Tighten all hose clamps and check hoses
for leaks.
If any hose (fuel or oil) lines are defective replace them
immediately.
Figure 15. Battery Connections
If the battery cable is connected
incorrectly, damage to the generator will
occur. Pay close attention to the polarity
of the battery when connecting the
battery.
Battery
This unit is of negative ground.
DO NOT
connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level is not
properly maintained. Add only distilled water when
replenishment is necessary. DO NOT over fill.
The battery is sufficiently charged if the specific gravity of
the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Check to see whether the battery cables are loose. Poor
contact may result in poor starting or malfunctions. Always
keep the terminals firmly tightened. Coating the terminals
with a thin film of grease will help to inhibit corrosion.
Summary of Contents for WHISPERWATT DCA-15SPX3
Page 2: ...PAGE 2 DCA 15SPX3 GENERATOR PARTS OPERATION MANUAL REV 2 09 03 01 ...
Page 23: ...DCA 15SPX3 GENERATOR PARTS OPERATION MANUAL REV 2 09 03 01 PAGE 23 NOTE PAGE ...
Page 29: ...DCA 15SPX3 GENERATOR PARTS OPERATION MANUAL REV 2 09 03 01 PAGE 29 NOTE PAGE ...
Page 47: ...DCA 15SPX3 GENERATOR PARTS OPERATION MANUAL REV 2 09 03 01 PAGE 47 NOTE PAGE ...
Page 131: ...DCA 15SPX3 GENERATOR PARTS OPERATION MANUAL REV 2 09 03 01 PAGE 131 NOTE PAGE ...