DCA-60SSAI — PARTS AND OPERATION MANUAL— FINAL COPY (09/15/01) — PAGE 29
DCA-60SSAI — CONTROL PANEL
The definitions below describe the controls and functions of
the DCA-60SSAI " Control Panel
Control Panel
Control Panel
Control Panel
Control Panel " (Figure 8).
1.
Frequency Meter –
Indicates the output frequency in
hertz (Hz). Normally 60 Hz ±1 Hz .
2.
AC Ammeter –
Indicates the amount of current the
load is drawing from the generator.
3.
ACVoltmeter –
Indicates the single phase output
voltage present at the UNV terminals.
4.
Pilot Lamp -
This lamp indicates the load is not properly
set. Readjust the load, or use the voltmeter change-
over switch to adjust phase position.
5.
Main Circuit Breaker –
This three-pole, 150 amp main
breaker is provided to protect the UNV voltage output
terminals from overload.
6.
Voltmeter Change-Over Switch –
This switch allows
the AC voltmeter to indicate phase to phase voltage
between any two phases of the output terminals or to
be switched off.
7.
Ammeter Change-Over Switch –
This switch allows
the AC ammeter to indicate the current flowing to the
load connected to any phase of the output terminals, or
to be switched off.
8.
Voltage Regulator Control –
Allows manual
adjustment of the generator’s output voltage.
Summary of Contents for WHISPERWATT DCA-60SSAI
Page 2: ...PAGE 2 DCA 60SSAI PARTS AND OPERATION MANUAL FINAL COPY 09 15 01 ...
Page 22: ...PAGE 22 DCA 60SSAI PARTS AND OPERATION MANUAL FINAL COPY 09 15 01 DCA 60SSAI GENERATOR DECALS ...
Page 27: ...DCA 60SSAI PARTS AND OPERATION MANUAL FINAL COPY 09 15 01 PAGE 27 NOTE PAGE ...
Page 51: ...DCA 60SSAI PARTS AND OPERATION MANUAL FINAL COPY 09 15 01 PAGE 51 NOTE PAGE ...
Page 61: ...DCA 60SSAI PARTS AND OPERATION MANUAL FINAL COPY 09 15 01 PAGE 61 NOTE PAGE ...
Page 151: ...DCA 60SSAI PARTS AND OPERATION MANUAL FINAL COPY 09 15 01 PAGE 151 NOTE PAGE ...