Shutdown Procedure - Engine Controller
(S/N 73002141
~
)
To shutdown the generator use the following procedure:
1. Place both the
MAIN
,
GFCI
and
LOAD
circuit breakers
as shown in Figure 45 to the "
OFF
“ position.
2. Place the
engine speed switch
in the “
LOW
” position
(Figure 73).
Figure 73. Engine Speed Switch (Low)
3. Let the engine cool by running it for 3-5 minutes with no
load applied.
4. Place the
Auto-Off/Reset-Manual
switch (Figure 74) to
the “
OFF/Reset
“ position.
Figure 74. Off/Manual Auto Switch (Off)
5. Verify that the
all
status LED on the MPEC display
(Figure 68) are "
OFF
" (not lit).
6. Remove all loads from the generator.
DCA-70SSJU SERIES — GENERATOR SHUT-DOWN PROCEDURE
Shutdown Procedure - Ignition Switch
(Up to S/N 73002140)
To shutdown the generator use the following procedure:
1. Place both the
MAIN
,
GFCI
and
LOAD
circuit breakers
as shown in Figure 45 to the "
OFF
“ position.
2. Place the
engine throttle control
in the “
LOW
” position
(Figure 71).
Figure 71. Engine Throttle Control (Low)
3. Let the engine cool by running it for 3-5 minutes with no
load applied.
4. Turn the
Ignition Key Switch
(Figure 72) to the “
OFF
“
position.
Figure 72. Engine Ignition Switch (Stop)
5. Remove all loads from the generator.
NEVER
stop the engine suddenly except
in an emergency.
DO NOT
use the
emergency stop switch a as method of
shutting down the generator. This switch is
ONLY
to be used in the event of an
emergency.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
:
Emergency Shutdown Procedure - Engine Controller
(S/N 73002141
~
)
1. To shut-down the engine in the event of an emergency,
switch the
MAIN
,
GFCI
and
LOAD
(Figure 45) circuit
breakers to “
OFF
” position.
2. Place the
Auto-Off/Reset-Manual
switch (Figure 74) to
the “
OFF/Reset
“ position.
Emergency Shutdown Procedure - Ignition Switch
(Up to S/N 73002140)
1. To shut-down the engine in the event of an emergency,
switch the
MAIN
,
GFCI
and
LOAD
(Figure 61) circuit
breakers to “
OFF
” position.
2. Turn the
ignition switch key
to the “
STOP
” position
(Figure 72).