page 52 — DCa180SSI/DCa180SSIu 60 hz gen. • operaTIon anD parTS manual — rev. #1 (08/02/10)
trOUbLeshOOting (DiagnOstic LaMp)
The engine controller of this generator diagnoses problems
that arise from the engine control system and the engine
itself. Press the diagnostic button (Figure 69) on the
diagnostic panel to determine if an engine malfunction has
occurred.
Figure 69. Diagnostic Panel
meThoD oF operaTIon
1. Normally, the diagnostic lamp will be
dimly
lit when
the
mpeC Control Switch
is placed in the
manual
position.
2. If engine trouble occurs, the diagnostic lamp will be
brightly
lit as long as the control switch is left in the
manual position.
3. The diagnostic lamp will indicate that an engine
malfunction has occurred.
NOTICE
For a complete understanding of error codes and
troubleshooting procedures, refer to the enclosed
engine instruction manual.
NOTICE
If the engine is cranked while the diagnostic switch is in
the “ON” position, the engine will not be stopped even if
the starter switch is turned to the “OFF” position. In such
case, turn the diagnostic switch to the “OFF” position.
Summary of Contents for Whisperwatt DCA180SSI