PAGE 26 — DCA20SPXU4F • OPERATION MANUAL — REV. #3 (09/18/19)
INSPECTION/SETUP
Day-to-day addition of coolant is done from the recovery
tank. When adding coolant to the radiator,
DO NOT
remove
the radiator cap until the unit has completely cooled. See
Table 8 for engine, radiator, and recovery tank coolant
capacities. Make sure the coolant level in the recovery tank
is always between the “H” and the “L” markings.
Operation in Freezing Weather
When operating in freezing weather, be certain the proper
amount of antifreeze (Table 9) has been added.
Cleaning the Radiator
The engine may overheat if the radiator fins become
overloaded with dust or debris. Periodically clean the
radiator fins with compressed air. Cleaning inside the
machine is dangerous, so clean only with the engine turned
off and the
negative
battery terminal disconnected.
AIR CLEANER
Periodic cleaning/replacement is necessary. Inspect air
cleaner in accordance with the
Isuzu Engine Owner’s
Manual
.
Table 8. Coolant Capacity
Engine and Radiator
2.3 gal (8.8 liters)
Reserve Tank
N/A
Table 9. Anti-Freeze
Operating Temperatures
Vol %
Anti-Freeze
Freezing Point
°C
°F
50
-37
-34
NOTICE
When the antifreeze is mixed with water, the antifreeze
mixing ratio
must be
less than 50%.
FAN BELT TENSION
A slack fan belt may contribute to overheating, or to
insufficient charging of the battery. Inspect the fan belt for
damage and wear and adjust it in accordance with the
John
Isuzu Engine Owner’s Manual.
The fan belt tension is proper if the fan belt bends 10 to 15
mm (Figure 22) when depressed with the thumb as shown
below.
Figure 22. Fan Belt Tension
BATTERY
This unit is of negative ground
DO NOT
connect in reverse.
Always maintain battery fluid level between the specified
marks. Battery life will be shortened, if the fluid level are
not properly maintained. Add only distilled water when
replenishment is necessary.
DO NOT
over fill. Check to see whether the battery
cables are loose. Poor contact may result in poor starting
or malfunctions.
Always
keep the terminals firmly
tightened. Coating the terminals with an approved battery
terminal treatment compound. Replace battery with only
recommended type battery. The battery type used in this
generator is BCI Group 27.
The battery is sufficiently charged if the specific gravity
of the battery fluid is 1.28 (at 68° F). If the specific gravity
should fall to 1.245 or lower, it indicates that the battery is
dead and needs to be recharged or replaced.
Before charging the battery with an external electric source,
be sure to disconnect the battery cables.
CAUTION
NEVER
place hands near the belts or fan
while the generator set is running.
Summary of Contents for WHISPERWATT DCA20SPXU4F
Page 2: ...PAGE 2 DCA20SPXU4F OPERATION MANUAL REV 3 09 18 19 PROPOSITION 65 WARNING ...
Page 41: ...DCA20SPXU4F OPERATION MANUAL REV 3 09 18 19 PAGE 41 GENERATOR WIRING DIAGRAM ...
Page 42: ...PAGE 42 DCA20SPXU4F OPERATION MANUAL REV 3 09 18 19 ENGINE WIRING DIAGRAM ...
Page 45: ...DCA20SPXU4F OPERATION MANUAL REV 3 09 18 19 PAGE 45 NOTES ...