PAGE 12 — DCA300SSJU4F2 60 HZ GENERATOR • OPERATION MANUAL — REV. #0 (06/26/18)
DIMENSIONS
SIDE VIEW
TOP VIEW
FRONT VIEW
H
I
G
A
F
B
C
E
MAXIMUM
LIFTING
POINT
19,000 lbs.
(8,618 kg)
D
300
Denyo
OFF
W
U
V
OFF
W-U
V-W
U-V
DECREASE
INCREASE
Engine Started
Shutdown
Pre-Alarm
Series 800 Controller
Alarm
Acknowledge
Screen
Change
Program/
Exit
Option
ECU
PSI
OIL PRESS
0
25
50
75
100
°F
WATER TEMP
100
140
180
220
260
°F
FUEL
E
½
F
RPMX10
SPEED
0
120
150
180
210
60
°F
DEF
E
½
F
ECU
Integrated Gauge Panel
VOLTS
0
12
18
24
30
%
0
50
100
Check
DEF
Emissions
Failure
Emissions
Failure
Regen
Needed
Regen
Inhibit
Low
Fuel
Table 3. Dimensions
Reference
Letter
Dimension in. (mm)
Reference Letter
Dimension in. (mm)
A
38.19 (970)
F
46.42 (1,179)
B
38.19 (970)
G
149.60 (3,800)
C
45.47 (1,155)
H
96.46 in. (2,450)
D
23.03 (585)
I
59.05 in. (1,500)
E
25.20 (640)
Figure 2. Dimensions