3

SPECIFICATIONS

OPERATING PRECAUTIONS

This is a kerosene, direct-fired, forced air heater. It’s intended use 
is primarily temporary heating of buildings under construction, 
alteration or repair.
Direct-Fired means that all of the combustion products enter the 
heated space. Even though this heater operates very close to 100 
percent combustion efficiency, it still produces small amounts 
of carbon monoxide. Carbon monoxide (called CO) is toxic. CO 
can build up in a heated space and failure to provide adequate 
ventilation could result in death. The symptoms of inadequate 
ventilation are:
• headache 
• dizziness
• 

burning eyes and nose 

• nausea
• 

dry mouth or sore throat

Be sure to follow advice about ventilation in the Safety 
Precautions section.
Forced Air means that a blower or fan pushes the air through the 
heater. Proper combustion depends upon this air flow; therefore, 
the heater must not be revised, modified or operated with 
parts removed or missing. Likewise, safety systems must not be 
circumvented or modified in order to operate the heater.
When the heater is to be operated in the presence of other people 
the user is responsible for properly acquainting those present 
with the safety precautions and instructions, and of the hazards 
involved.

SAFETY PRECAUTIONS

1.  Recommended for use with No.1-K kerosene fuel. Factory tested 

for use with No.2-K kerosene, No.1 or No.2 Diesel, No.1 or No.2 
fuel oil or JP8 Jet A fuel and these fuels may be used as well. Never 
use gasoline, biodiesel, oil drained from crank cases, naphtha, 
paint thinners, alcohol or any other highly flammable fuels.

2.   Check the heater thoroughly for damage. DO NOT operate a 

damaged heater.

3.  DO NOT modify the heater or operate a heater which has been 

modified from its original condition.

4.  Suitable for either outdoor or indoor use where adequate 

ventilation is provided. Never use in areas normally for 
habitation. Not for use where exposed to weather.

5.  Use in well ventilated areas, provide at least 2 sq. ft. (0.19 

sq. m.) of opening near the floor and 2 sq. ft. (0.19 sq. m.) 
near the ceiling directly to outdoors. Increase air openings as 

marked for each additional heater.

6.  Always keep combustibles, like paper and wood at least 8 

ft. (2.4 m) from the heater outlet and 3 ft. (1.0 m) from 
the top, sides and inlet. Locate 10 ft. (3.0 m) from canvas 
or plastic coverings and secure them to prevent flapping 
movement. 

7.  Caution: Due to the high surface and exhaust temperatures, 

adults and children must observe clearances to avoid burns 
or clothing ignition. Do Not Touch. Keep children, clothing, 
and combustible away.

8.  Install the heater such that it is not directly exposed to water 

spray, rain and / or water.

9.  Never use in areas normally for habitation and /or where 

children may be present.

10.  Operate only on a stable, level surface. (MH50KR & 

MH75KTR – See wood floor warning).

11.  Do not use with duct work. Do not restrict inlet or exit.
12.  Use only with electrical power specified. The electrical 

connection and grounding must comply with National 
Electrical Code – ANSI/NFPA 70 (USA) and CSA C22.1 
Canadian Electrical Code, Part 1 (Canada).

13.  Use only a properly grounded 3-prong receptacle or 

extension cord.

14.  Do not move, handle, or service while hot or in operation.
15.  Use only in accordance with local, state (provincial) or 

national requirements, ordinances and codes.

OPERATING INSTRUCTIONS

UNPACKING

1.  Remove heater from carton.
2.  Remove all protective material which may have been applied 

to the heater for shipment.

3.  Check the heater for possible shipping damage. If any 

damage is found immediately contact the manufacturer at 
800-251-0001.

ASSEMBLY 

(For 125,000, 175,000 and 210,000 BTU/hr models 

only, see figure 1, page 8.)
Wheels and handles are found in the shipping carton along with 
mounting hardware. The wheels, axle and mounting hardware 
are in a package. Tools required are a 5/16” nut driver, 3/8” open 
or adjustable wrench and standard pliers.
1.  Assemble the wheels onto the wheel support as shown.
2.  Install one of the cotter pins into the hole on one end of 

CAUTION: CSA certified for use with only No. 1-K kerosene fuel.
Factory Tested: Kerosene, Diesel #1 and #2, Fuel Oil #1 and #2, JP8 (Jet A Fuel)

 

 

 

 

 

Model  50KR  75KTR  125KTR 175KTR  210KTR

Burn Rate: 

50,000 Btu/hr (14.7 kW)  75,000 Btu/hr (22 kW) 

125,000 Btu/hr (37 kW) 

175,000 Btu/hr (51 kW) 

210,000 Btu/hr (61.5 kW)

Fuel Rate: 

0.37 gal/hr (1.4 L/hr) 

0.55 gal/hr (2.1 L/hr) 

0.96 gal./hr (3.5 L/hr)  

1.3 gal/hr (5.0 L/hr) 

1.6 gal/hr (6.0 L/hr)

Electrical Input: 

115V, 60Hz, 3.5a 

115V, 60Hz, 4a 

115V, 60Hz, 5.5a 

115V, 60Hz, 5.5a 

115V, 60Hz, 5.5a

Line Protection: 

10 amps 

10 amps 

20 amps 

20 amps 

20 amps

Min. Operating Voltage:  110V 

110V 

110V 

110V 

110V

Pressure Setting: 

3.5 psig (24 kPa) 

4.2 psig (29 kPa) 

5.0 psig (35 kPa) 

6.8 psig (47 kPa) 

8.4 psig (58 kPa)

Max. Outlet Temperature:  1450

o

F (787

o

C) 1450

o

F (787

o

C) 1450

o

F (787

o

C) 1450

o

F (787

o

C) 1450

o

F (787

o

C)

Fuel Tank Capacity: 

4 gallons (15.1 L) 

6 gallons (22.7 L) 

8.45 gallons (32 L) 

13.5 gallons (51 L) 

13.5 gallons (51 L)

Ignition: 

Direct Spark, Continuous   Direct Spark, Continuous  Direct Spark, Continuous  Direct Spark, Continuous 

Direct Spark, Continuous

Spark Generator: 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma 

Igniter 13 kV, 10ma

Primary Safety Control:  Solid State Control 

Solid State Control 

Solid State Control 

Solid State Control 

Solid State Control

Certification: 

 

 

 

 

 

 

 

 

Summary of Contents for F270255

Page 1: ...formed by a qualified service agency This is an unvented portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to page 3 KEROSENE FORCED AIR HEATER 2019 OPERATING INSTRUCTIONS AND OWNER S MANUAL READ INSTRUCTIONS CAREFULLY Read and follow all instructions Place instructions in a safe place for future reference Do not all...

Page 2: ...SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE ...

Page 3: ...tion Do Not Touch Keep children clothing and combustible away 8 Install the heater such that it is not directly exposed to water spray rain and or water 9 Never use in areas normally for habitation and or where children may be present 10 Operate only on a stable level surface MH50KR MH75KTR See wood floor warning 11 Do not use with duct work Do not restrict inlet or exit 12 Use only with electrica...

Page 4: ...beyond the heater in all directions HEATER START UP 1 MH50KR Plug the heater into a grounded 115V 60 Hz 1 Ø outlet MH75KTR MH125KTR MH175KTR MH210KTR Turn thermostat to lowest setting and make sure On Off switch is Off Plug the heater into a grounded 115V 60 Hz 1 Ø outlet Turn thermostat to highest setting Start heater by pushing toggle switch to On position light signifies switch is in ON positio...

Page 5: ...of fuel and air flow Pressure will gradually increase giving improper fuel air mixture and excess odor and smoke If this occurs replace the fuel nozzle 5 FUEL TANK Clean twice a season during frequently used periods clean twice a month Drain and flush the fuel tank with clean fuel oil ANNUAL SCHEDULE 1 AIR OUTPUT FILTER Remove the air output filter and tap the contaminated side gently on a solid o...

Page 6: ...owing troubleshooting guide for unit status and corrective action if necessary SYMPTOM TROUBLE SHOOTING High limit switch Open Circuit 1 Make sure heater is cooled off toggle switch to OFF position wait 5 minutes and retry Sparks calling for flame but 1 Check wiring to motor per wiring schematic in manual no or slow motor operation 2 Make sure that the pressure gauge is in place and not damaged 3 ...

Page 7: ...D SET MOTOR CAPACITOR CIRCUIT BOARD 18AWG YELL 18AWG YELL 18AWG RED 18AWG RED 18AWG WHT 18AWG BLK 18AWG GRN 18AWG PURPLE 18AWG PINK 18AWG PINK 1 2 3 4 5 6 18AWG PURPLE THERMOSTAT 18AWG BLUE 7 8 ELECTR0DE 18AWG GRN 17AWG BLK 9 10 RED LED 11 12 18AWG BLUE 17AWG BLK 24AWG BLK 24AWG RED 18AWG BLK 18AWG WHT CAD CELL 18AWG BLUE THERMOSTAT 18AWG PURPLE COM1 I2 I1 M2 M1 L N 18AWG PURPLE 18AWG GRN 18AWG BL...

Page 8: ...r Pump Insert 19 26898 26898 26898 26898 Receptacle 110V 20 22104 22104 22104 22104 AC Receptacle Cover 21 26833 26833 26833 26833 26833 Air Pump Cylinder 22 21810 21810 21810 21810 21810 Outlet Housing 23 21812 21812 21812 21812 21812 Inlet Housing 24 22257 22257 22257 Burner Head Ass y 25 F221887 F221887 F221887 F221887 F221887 Kit Filter 26 21814 21814 21814 21814 21814 Outlet Filter 27 21815 2...

Page 9: ...s and Owner s Manual 9 1 2 3 4 5 6 7 9 10 11 13 14 15 16 17 18 19 20 21 24 25 26 53 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 45 46 47 51 52 8 12 22 23 33 48 49 50 27 Kerosene Forced Air Heater Model MH50KR MH75KTR MH125KTR MH175KTR MH210KTR Filter Kit 51 52 ...

Page 10: ...nclude the model number date of purchase and description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase Mr Heater Inc will repair or replace this product free of charge if it has been proven to be defective within the 1 year period and is returned at...

Page 11: ...ctué par un fournisseur de services d entretien qualifié Cet appareil de chauffage portatif n est pas ventilé Il utilise l oxygène de l air ambiant Une circulation d air adéquate doit être assurée pour la combustion et la ventilation Voir page 3 APPAREIL DE CHAUFFAGE À AIR PULSÉ AU KÉROSÈNE GUIDE D UTILISATION ET INSTRUCTIONS DE FONCTIONNEMENT LISEZ SOIGNEUSEMENT LES INSTRUCTIONS Lisez et observez...

Page 12: ...QUE DE CAUSER LA MORT DES BLESSURES GRAVES ET DES DOMMAGES OU DES PERTES MATÉRIELLES RÉSULTANT D INCENDIE D EXPLOSION DE BRÛLURE D ASPHYXIE D INTOXICATION AU MONOXYDE DE CARBONE OU D ÉLECTROCUTION SEULES LES PERSONNES APTES À COMPRENDRE ET À RESPECTER LES INSTRUCTIONS DEVRAIENT UTILISER OU EFFECTUER L ENTRETIEN DE CET APPAREIL DE CHAUFFAGE SI VOUS AVEZ BESOIN D AIDE OU D INFORMATION AU SUJET DE L ...

Page 13: ...ier et le bois à au moins 2 4 m 8 pi de la sortie de l appareil de chauffage et à 1 0 m 3 pi du dessus et des côtés de l appareil ainsi que de la prise d air Placez l appareil à 3 m 10 pi des toiles et des revêtements plastiques et fixez les afin d empêcher tout battement 7 Attention En raison des températures élevées à la surface et à la sortie les adultes et les enfants doivent respecter les dis...

Page 14: ...e mise à la terre de 115 V 60 Hz 1 Ø MH75KTR MH125KTR MH175KTR et MH210KTR Réglez le thermostat au minimum et assurez vous que l interrupteur est à OFF Branchez le cordon de l appareil de chauffage dans une prise mise à la terre de 115 V 60 Hz 1 Ø Réglez le thermostat à sa position la plus élevée Démarrez l appareil de chauffage en mettant l interrupteur à ON Marche La lumière s allume à la positi...

Page 15: ...nduits du gicleur et entraînera une diminution du débit d air et de combustible La pression augmentera graduellement ce qui déséquilibrera le mélange air combustible et produira un surplus de fumée et d odeur Dans un tel cas remplacez le gicleur 5 RÉSERVOIR DE COMBUSTIBLE Nettoyez le deux fois par saison au cours des périodes d utilisation intensive nettoyez le deux fois par mois Rincez et vidange...

Page 16: ...roidi appuyez sur le bouton de réinitialisation et essayez de nouveau Circuit ouvert du contacteur de commande maximale 2 clignotements Verrouillage du système 1 Vérifiez le câblage vers le moteur selon le schéma de câblage du présent guide 2 Assurez vous que le bouchon du manomètre est bien en place et qu il n est pas endommagé 3 Réglez la pression pour assurer le bon fonctionnement de l appareil...

Page 17: ...WG 18 TRANSFORMATEUR D ALLUMAGE NOIR AWG 17 ÉLECTRODE RGE AWG 18 RGE AWG 18 CELLULE AU CADMIUM SCHÉMA DE LA COMMANDE DE FLAMME la position des connexions peut différer sur le circuit imprimé INTERRUPTEUR MARCHE ARRÊT NOIR AWG 18 BLC AWG 18 VRT AWG 18 MODÈLES 125KT 175KT ET 210KT UNIQUEMENT PRISE C A ORG AWG 18 CONDENSATEUR DU MOTEUR ORG AWG 18 ROSE AWG 18 ROSE AWG 18 MOTEUR BLC AWG 18 NOIR AWG 18 ...

Page 18: ...6831 F226831 F226831 F226831 F226831 Ensemble de rotor Rotor de pompe à air avec ailettes Raccord de nylon pour pompe à air 19 26898 26898 26898 26898 Réceptacle 110 V 20 22104 22104 22104 22104 Couvercle de réceptacle 21 26833 26833 26833 26833 26833 Cylindre de pompe à air 22 21810 21810 21810 21810 21810 Boîtier de sortie 23 21812 21812 21812 21812 21812 Boîtier d admission 24 22257 22257 22257...

Page 19: ... 4 5 6 7 9 10 11 13 14 15 16 17 18 19 20 21 24 25 26 53 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 45 46 47 51 52 8 12 22 23 33 48 49 50 27 Appareil de chauffage à air pulsé au kérosène Modèles MH50KR MH75KTR MH125KTR MH175KTR MH210KTR Kit de Filtre à Carburant Filtre à carburant 51 52 ...

Page 20: ... dans toutes vos communications avec nous GARANTIE LIMITÉE Mr Heater Inc garantit ses appareils de chauffage et ses accessoires contre les défauts de matériel et de main d œuvre pour une période de un an à partir de la date d achat Mr Heater Inc réparera ou remplacera ce produit sans frais s il est démontré qu il est devenu défectueux pendant la période de garantie et qu il est retourné à Mr Heate...

Page 21: ... realizarlo una agencia de servicio calificada Este es un calentador portátil a gas sin fuente propia de ventilación Utiliza el aire oxígeno del área en la cual se emplea Debe suministrarse el aire necesario para la ventilación y la combustión Ver página 3 CALENTADOR DE CALDEO A AIRE FORZADO A KEROSENE INSTRUCCIONES DE USO Y MANUAL DEL USUARIO LEA CUIDADOSAMENTE LAS INSTRUCCIONES lea y siga todas ...

Page 22: ...MACIÓN ACERCA DEL CALENTADOR COMO UN MANUAL DE INSTRUCCIO NES ETIQUETAS ETC PÓNGASE EN CONTACTO CON EL FABRICANTE ADVERTENCIA PELIGRO DE INCENDIO QUEMADURAS INHALACIÓN Y EXPLOSIÓN MANTENGA LOS COMBUSTIBLES SÓLIDOS TALES COMO MATERIALES DE CONSTRUC CIÓN PAPEL O CARTÓN A UNA DISTANCIA SEGURA DEL CALENTADOR COMO SE RECOMIENDA EN LAS INSTRUCCIONES NUNCA USE EL CALENTADOR EN ESPACIOS QUE CONTENGAN O PO...

Page 23: ... la salida del calentador y a 3 pies 1 0 m de distancia de la parte superior los costados y la entrada Colóquelo a 10 pies 3 0 m de las cubiertas de lona o plástico y asegúrelas de modo que no para que se mantengan estáticas 7 Cuidado dadas las elevadas temperaturas de la superficie y del escape tanto los adultos como los niños deben mantener la distancia adecuada para evitar quemaduras o la que p...

Page 24: ... no son adecuados para usarse en pisos de madera u otros materiales combustibles Cuando lo use debe colocar el calentador sobre un material aislante adecuado de al menos 1 pulgada de espesor y que sobresalga 3 pies o más del calentador en todas las direcciones ENCENDIDO DEL CALENTADOR 1 MH50KR enchufe el calentador en un tomacorriente con clavija de tierra de 115 V 60 Hz 1 Ø MH75KTR MH125KTR MH175...

Page 25: ...pie el calentador dos veces por temporada con más frecuencia cuando hay polvo Quite el polvo acumulado del transformador quemador motor y aspas del ventilador con aire comprimido Limpie el área con un paño seco y limpio Inspeccione el área para asegurarse de quitar todos los materias extrañas especialmente alrededor del quemador y del área de combustión 3 CÉLULA DEL CAD Limpie la parte de vidrio d...

Page 26: ...cesaria SÍNTOMA RESOLUCIÓN DE PROBLEMAS Interruptor limitador máximo en circuito abierto 1 Asegúrese de que el calentador se enfríe por completo cambie el interruptor a la posición OFF espere 5 minutos e inténtelo nuevamente Chispas piden llama pero el motor no funciona o funciona lentamente 1 Verifique el cableado al motor según el esquema de cableado del manual 2 Asegúrese de que el indicador de...

Page 27: ...O 18 AWG BLANCO 18 AWG VERDE TOMACORRIENTE DE CA 125KT 175KT 210KT ÚNICAMENTE 18 AWG NARANJA 18 AWG NARANJA 18 AWG ROSADO 18 AWG ROSADO CONDENSADOR DEL MOTOR 18 AWG ROJO 18 AWG ROJO TRANSFORMADOR DE ENCENDIDO MOTOR 18 AWG PÚRPURA 18 AWG PÚRPURA CÉLULA DEL CAD DIAGRAMA DE CONTROL DE LA LLAMA las conexiones pueden no estar en la misma posición en la placa de circuito TIC 17 AWG NEGRO 17 AWG NEGRO EL...

Page 28: ...R MH125KTR MH175KTR MH210KTR 29 21866 21866 21867 21867 21867 Conjunto de control de la llama 30 21816 21816 21816 21816 21816 Soporte de control de la llama 31 F226865 F226865 F226865 F226865 F226865 Sensor de llama de la célula del cad 32 21882 21868 21869 21870 21871 Conjunto del cilindro de la cámara de combustión 33 26959 26959 26959 26959 26959 Tapa de combustible 34 26910 26910 26910 26910 ...

Page 29: ... 9 1 2 3 4 5 6 7 9 10 11 13 14 15 16 17 18 19 20 21 24 25 26 53 28 29 30 31 32 34 35 36 37 38 39 40 41 42 43 44 45 46 47 51 52 8 12 22 23 33 48 49 50 27 Calentador de queroseno a aire forzado Modelos MH50K MH75KT MH125KT MH175KT MH210KT Filtre à carburant Kit Filtre à Carburant 51 52 ...

Page 30: ...orios contra defectos de materiales y mano de obra por un período de 1 año a partir de la fecha de compra Mr Heater Inc reparará o reemplazará este producto sin cargo si presentara desperfectos dentro del primer año tras realizada la compra siempre y cuando el cliente cubra los gastos de la devolución y presente el comprobante de compra a Mr Heater Inc dentro del período de garantía Algunos estado...