background image

Step 16:

 Place the Propane Cylinder into the 

Base. Then lift the cylinder Cap Support, to hold 
the cap in position.  Attach the Front Cover to the 
Back Cover.  Then lower Cap. 

 

 

 

Gas Requirements: 

The heater comes with a regulator for hook-up to 
a standard propane gas cylinder set up for vapor 
withdrawal (operated with the cylinder vertical).  
The gas cylinder must be constructed and 
marked in accordance with specifications of the 
U.S. Department of Transportation for propane 
cylinders.  Never connect the heater to an 
unregulated cylinder.  The heater is shipped from 
the factory for use with propane never substitute 
gases.   

 

CAUTION: 

When the heater is to be operated in 

the presence of other people the user is 
responsible for properly acquainting those 
present with safety precautions, and other 
hazards involved.  

 

Fuel Connection: 

1.  Use a 20-pound (5-gallon) vapor 

withdrawal propane cylinder. Not 
supplied with the heater. 

2.  Place the cylinder in the heater base 

with the valve accessible. 

3.  Connect the POL fitting of the hose & 

regulator assembly to the propane 
cylinder by rotating the plastic POL nut 
clockwise onto the propane cylinder’s 
valve outlet and securely tighten. 

4.  Make sure that the safety valve is turned 

off then open the cylinder’s valve and 
check all gas connection with a soap 
and water solution. DO NOT USE A 
FLAME. The gas connections to check 
include those in the heater base and the 
connections in the burner assembly. 

To Light: 

 

Caution

: Never leave heater operating 

unattended. 

1.  Remove the Cylinder cover on the base. 

2.  Make sure that all gas connections 

where checked with a soap and water 
solution before igniting heater, as 
described in the fuel connection section 
of this manual. 

3.  Fully open the valve on the propane 

cylinder. 

4.  Turn safety gas control knob to “pilot” 

position. 

5.  Push in and hold the gas control knob 

then push and release the ignition 
button repeatedly until there is a flame 
at the pilot.  If the ignition button does 
not work the pilot may be lit using a 
match through the access hole, found 
under the emitter base. 

6.  Keep the control knob depressed for at 

least 30 seconds after pilot ignition then 
release control knob. 

7.  Turn the burner on to maximum rate 

then reduce to desired burner setting. 

8.  Replace the cylinder cover on the base 

to cover the propane cylinder. 

 

Caution

: White smoke may appear 

around the emitter screen during the 
first few minutes of the initial burning. 

Relight After Shutdown: 

1.  Turn the gas control knob to “OFF” 

position. 

2.  Wait 5 minutes. 

3.  Restart following “To Light” procedure. 

\\Commserv\Users\EGI_Shared\Engineering\Labels & Manuals WIP\MH40PH\MH40PH Manual.doc 

Page 8 of 11 

06/08 Rev A

Summary of Contents for MH40PH

Page 1: ...S HEATER GENERAL HAZARD WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOR...

Page 2: ...at there is ample fresh air ventilation DO NOT use in buildings garages or other enclosed spaces If at any time gas odor is detected IMMEDIATELY DISCONTINUE operation until the source of gas has been...

Page 3: ...efore you return Properly trained service people must repair the leak check for further leakages and them relight the appliance for you ODOR FADING NO ODOR DETECTED Some people cannot smell well Some...

Page 4: ...e all components from package and inspect parts Packaging includes Nut Bolt Pack Containing 4pcs 3 16 24x3 8 screws 12pcs 1 4 20x3 4 bolts 12pcs 1 4 20 nuts 24pcs 1 4 flat washers 12pcs 1 4 lock washe...

Page 5: ...has Wheels please assemble the wheels as Attachment 2 before Step 5 Attach 3 Legs Post Support Assembly to Base 6 bolts 1 4 20 3 4 12 flat washers 6 lock washers 6 nuts Step 6 Install Post onto Post...

Page 6: ...OFF Open the Propane Cylinder Valve If bubbles appear at the connection there is a leak and it must be tightened until no bubbles appear MAKE SURE THERE IS NO LEAKS Close the Propane Cylinder Valve t...

Page 7: ...several drops of the Leak Check Solution Step 10 to the hose gas line connection Make sure the Heater Control Knob is OFF Open the Propane Cylinder Valve If bubbles appear at the connection there is...

Page 8: ...en the cylinder s valve and check all gas connection with a soap and water solution DO NOT USE A FLAME The gas connections to check include those in the heater base and the connections in the burner a...

Page 9: ...ed in accordance with chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 Only recoat those portions of the heater post base assembly with high temperature 120...

Page 10: ...must show heater model number item number part number and description We recommend that only parts supplied by the manufacture be used on this unit A locally purchased part may appear to be identical...

Page 11: ...Commserv Users EGI_Shared Engineering Labels Manuals WIP MH40PH MH40PH Manual doc Page 11 of 11 06 08 Rev A...

Page 12: ...06 08 Rev A...

Reviews: