In case the manifold pressure is changed for this reason, the altitude label in the conversion kit must be completed and affixed to the unit:
TABLE 5: Natural Gas
Heating Values at Altitude
TABLE 6: Propane Gas
Heating Values at Altitude
Model
Altitude 0-2000 ft. (0-610m)
Altitude 2000-3000 ft. (610-910mm)
Manifold Pressure
Input Rating
Manifold Pressure
Input Rating
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
MHRP37GL
6.4
1.6
37,000
10,844
5.90
1.47
35,520
10,410
Model
Altitude 0-2000 ft. (0-610m)
Altitude 2000-3000 ft. (610-910mm)
Manifold Pressure
Input Rating
Manifold Pressure
Input Rating
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
MHRP37GL
7.5
1.87
37,000
10,844
6.91
1.72
35,520
10,410
Model
Altitude 3000-4000 ft. (910-1220m)
Altitude 4000-4500 ft. (1220-1350mm)
Manifold Pressure
Input Rating
Manifold Pressure
Input Rating
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
MHRP37GL
5.42
1.35
34,040
9,976
5.18
1.30
33,300
9,760
Model
Altitude 3000-4000 ft. (910-1220m)
Altitude 4000-4500 ft. (1220-1350mm)
Manifold Pressure
Input Rating
Manifold Pressure
Input Rating
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
[“ W.C.]
[kPa]
[BTU/Hr]
[W]
MHRP37GL
6.35
1.58
34,040
9,976
6.08
1.51
33,300
9,760
This appliance was converted on ______ (day-month-year)
for operation at ____ ft.(___m) altitude by ____________
(name and address of the organization making this conver
-
sion) which accepts the responsiblity that this conversion
has been properly made.
Manifold pressure adjustment____W.C. Input rating____
Btu/hr
HIGH ALTITUDE OPERATION
This Unit heater is factory configured for altitudes from 0 – 2,000 ft above sea level. Above 2000 ft. (610m), manifold pressure must be
adjusted according to the following tables: