Electrical Connection of
AromaSteam System

AromaSteam

Plug

120 VAC

Outlet

(grounded receptacle

required)

Request Cable
24 VAC

to steam generator
(see below)

AromaSteam Wiring
Schematic

AromaSteam Connections

CAUTION

!

This AromaSteam system is factory wired. If

the power cord of the Aroma Steam system is damaged it
must be replaced by the Sussman-Automatic service
department or similarly qualified personnel in order to
avoid an electric shock hazard. All electrical connections to
be made by a licensed, qualified electrician. Disconnect all
power to the steam generator before
making power connections.

IMPORTANT NOTE:

AromaSteam is for use with iSteam

®

and iTempoPlus

®

controls only.

1. Disconnect all power to the Mr.Steam steambath

generator and remove the top cover.

2. Run the request cable from the AromaSteam System

through one of the knock outs in the side of the
steambath generator. Use a strain relief bushing
or grommet to prevent chafing.

3. Locate the two quick connect tabs labeled "AROMA"

on the PC board in the location show.

4. Connect the request cable to the terminals.

The terminals are not polarized.

6

Figure 5

Pressure Valve

Injector
Hose

Push Button

AromaSteam

Metering Pump

START-UP

Initial Priming of the Pump

1. Insure Mr.Steam scent container is full.

2. Insert the short injector hose onto the tip of the injector (see Fig. 5).

3. Unscrew the pressure end nut from the pump head and remove the

pressure hose from the pressure valve.

4. Insert the open end of the injection hose onto the pressure valve

(see Fig. 5).

5. Draw liquid from the injector slowly and evenly. Continue until the

injector is full of liquid.

6. If you have drawn up the injector completely and no liquid is in the

injector, remove the injector hose from the pressure valve.

7. Drain injector. Repeat steps until the injector is filled.

8. Save the oil injector as it will be needed when new oils are used.

Filling the Pressure Hose

1. Insure the AromaSteam System is primed and the scent container

is full.

2. Locate the Push-button at the rear of the metering pump

(see Fig. 6). Depress this push-button to start metering pump.

3. Continue to depress push-button until the pressure hose is filled

with liquid.

IMPORTANT NOTE:

Push button to be used only for initial filling

of the pressure hose, and after new oil bottles are installed.

Figure 6

Summary of Contents for aromasteam

Page 1: ...mr steam Feel Good Inc AromaSteam Installation Operation Maintenance Manual ...

Page 2: ...operation with this system The use of any oils other than Mr Steam oils may introduce excessive concentration of oil into the steam room resulting in a health hazard Vapors may cause drowsiness and dizziness Keep out of the reach of children In case of contact with eyes rinse immediately with plenty of water and seek medical advice If swallowed rinse mouth with water only if the person is consciou...

Page 3: ...ect to moisture condensation or similar high humidity envi ronments 4 Do not install AromaSteam Systems outdoors 5 Do not install AromaSteam Systems in a location where water could freeze 6 Do not install AromaSteam Systems near flammable or corrosive materials and chemicals Installation in areas having high concentrations of chlorine such as pool equipment room should be avoided CAUTION 6 ft Pres...

Page 4: ...ng T 2 T must face downward as shown in figure 2 3 Screw the atomizing nozzle into 90 T fitting using teflon tape on the threads IMPORTANT NOTE Follow the installation instructions for the steam pipeline in the Mr Steam Steam Bath Installation and Operation Manual Visit www mrsteam com to download this document Steam Line 90 T Figure 2 1 2 NPT 4 Installation of Pressure Hose to AromaSteam System 1...

Page 5: ...on end nut 4 Firmly push the hose onto the cone of the suction valve at the pump head 5 Screw the suction end nut to the suction valve IMPORTANT NOTE HAND TIGHTEN ONLY Max ht 6 ft iSteam Steam Line Typical Mr Steam Steam Generator Cable to Steam Generator request cable Atomzer Nozzle Pressure Hose 90 T Suction Hose Scent Container Pump Line Cord 120V grounded receptacle required AromaSteam System ...

Page 6: ...t tabs labeled AROMA on the PC board in the location show 4 Connect the request cable to the terminals The terminals are not polarized 6 Figure 5 Pressure Valve Injector Hose Push Button AromaSteam Metering Pump START UP Initial Priming of the Pump 1 Insure Mr Steam scent container is full 2 Insert the short injector hose onto the tip of the injector see Fig 5 3 Unscrew the pressure end nut from t...

Page 7: ...ma oils will automatically be pumped into the steam line at preset intervals Adjusting the Amount of Oil Deliver The AromaSteam system has been factory set to deliver a suitable amount of aromatic oil into a typical sized steam room Please contact the MrSteam Technical Service Department before changing this setting Increasing the settings may introduce excessive concentra tion of oil into the ste...

Page 8: ...il into steam room 1 Check if voltage is available 2 Check liquid level in scent container Replenish liquid if necessary 3 Check for air bubbles in the suction hose or the pump head To eliminate air bubbles see Priming Pump 4 Check valves for contamination Clean valves if necessary 5 Check filter in container for contamination Rinse filter under clean water 6 Check the pressure hose for kinking or...

Reviews: