14 Technical data
Maschinenfabrik Reinhausen GmbH 2020
381
6385142/08 EN
ETOS
®
ED
Storage temperature
Standard
-25...+70°C
Arctic with thermostat-controlled
additional heating
-40 to +70°C
In the temperature
range of -40…-25 °C,
all heaters must be in
operation continuously.
HiTemp
-25...+70°C
Air pressure
Corresponds to 2000 m above sea level
Table 138: Permissible ambient conditions
14.5 ISM® assemblies
14.5.1 Voltage supply
G1 PULS QS3.241
Permissible voltage range
85 to 276 V AC
88 to 375 V DC
V
N
: 100 to 240 V AC
U
N
: 110 to 300 V DC
Permissible frequency range
50/60 Hz
Nominal power consumption
55 W
Maximum power consumption (continuous)
70 W
Table 139: Voltage supply
14.5.2 Voltage supply
OT1205 (MR/N)
Permissible voltage range
85 to 265 V AC / V DC
V
N
: 100 to 240 V AC
V
N
: 100 to 220 V DC
Permissible frequency range
50/60 Hz
Power consumption
55 W
Internal fuse (2x)
250 V; 2 A; 5 x 20 mm, "delayed-action"
characteristic
Table 140: Standard design with wide range power supply