6 Mounting
Maschinenfabrik Reinhausen GmbH 2020
68
6385142/08 EN
ETOS
®
ED
Also take numbers after the decimal point into account.
10. If the correction value
|
C
|
is less than 0.5 tap-change indicator sections,
no further action is required. Refer to item 18 for how to proceed next.
11. Use the hand crank to crank in the direction in which the determined
value A or B was higher (example: counter-clockwise, because B > A)
until the diverter switch operation begins.
12. Once the diverter switch operation begins, continue turning another 8
hand crank revolutions in the same direction to correctly complete the di-