5 Mounting
Maschinenfabrik Reinhausen GmbH 2020
40
4983703/01 EN
VACUTAP
®
VV-Ex
9. Apply suitable corrosion protection to cut edges of the drive shaft's protec-
tive cover.
10. Seal joins after installation, e.g. by painting over them.
You will find more information about surface treatment and detailed informa-
tion about repairing damage to the protective layer in the repair instructions.
These are available from Maschinenfabrik Reinhausen GmbH's Technical
Service department on request.
5.2 Preparatory work
Perform the work stated below before installing the on-load tap-changer in
the transformer.
5.2.1 Fitting mounting flange on transformer cover
A mounting flange is required for fitting the on-load tap-changer head on the
transformer cover. This can be supplied as an option or can be produced by
the customer. Mounting flanges made by the customer must comply with the
installation drawings in the appendix.
►
NOTICE!
Fit mounting flange on transformer cover (pressure tight).En-
sure that the sealing face makes complete contact and is not damaged.
Figure 14: Mounting flange
5.2.2 Fitting stud bolts on mounting flange
To attach the stud bolts to the mounting flange, use a tracing template. This
can be provided upon request free of charge for the initial installation of the
on-load tap-changer.
1. Place tracing template on mounting flange and use the four markings to
align.