33
Dew point alarm: press
or
button to turn on/off dew point alarm
function. If the Alarm Switch is on, manually adjust the current ambient
temperature and humidity, the corresponding dew point temperature can
be indicated on the lower left corner of screen; if the dew point
temperature value exceeds the preset temperature, device will alarm with
setting alarm color.
Alarm Color
Alarm Color can select as: Auto, Black, White, Red, Orange, Yellow,
Green, Blue, Gray, and Purple. Default setting is Auto, which is no color
alarm.
Dew point temperature shown on lower left corner
:
dew point temperature can be defined as a temperature of air cooled
to saturation in the case that both the water vapor content and pressure
in air are consistent, which is related to ambient temperature and
humidity.
Analysis Setup
Summary of Contents for IR-CAM-B-70
Page 7: ...iv...
Page 38: ...31 1 2 fusion 1 4 fusion 3 4 fusion...
Page 55: ...1 Uncooled Focal Plane Infrared Cameras IRSee Report Software User Manual...
Page 68: ...11...
Page 69: ...12...
Page 70: ...13...
Page 71: ...14...