Sampling Time Approx. 1 second.
* Input : one pulse per round, 60 RPM
≧
Relay Output
Number
2 relays
Function
Relay 1 :
Control relay.
Relay 2 :
High/Low alarm relay.
Max load
0.5 ACA/250 ACV
0.5 DCA/24 DCV
* Do not apply the relay
contact load current
> 0.5 A, other wise the
relay may be damaged
permanently without
warranty.
Setting Value
Control value setting.
Alarm high limit value setting.
Alarm low limit value setting.
Pulse no. of each round.
Roller diameter value setting.
Hysteresis value setting.
* Setting for RPM, m/min., ft/min.
Input Signal
Pulse
Time base
Quartz crystal
External
DC 12 V, 50 mA max.
Power Supply
Data Output
RS 232 PC serial interface.
Operating
0 to 50 .
℃
Temperature
Operating
Less than 80% R.H.
Humidity
Power Supply
90 to 260 ACV, 50/60 Hz.
Power
Approx. 4.7 VA/AC 110V.
Consumption
Approx. 5.3 VA/AC 220V.
Weight
384 g/ 0.84 LB.
Dimension
DIN size : 96 x 48 mm.
Depth : 110 mm.