LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
Appendix H:
Servicing the Fan Module
Tools
•
6-inch flat-tip screwdriver
•
Possibly a replacement Fan module
Procedure
LD400
The procedure for cleaning/replacing the Fan module of the LD400 may be performed only at the
factory!
LD800
The procedure for cleaning/replacing the Fan module of the LD800 is as follows:
1. Slightly loosen the two captive screws fastening the jumper cable guide – see
– slide the guide to the top of the rails, then tighten the screws to hold the
guide in position.
2. Remove the panel with vents by loosening the four captive screws.
3. Carefully remove the pad (air filter) that is on the inside of the panel. If the pad is dirty,
wash it with water and dry it. Return the pad to its place.
4. To replace the fan, loosen the two captive screws and pull out the fan tray. Check/replace
the fan tray.
5. Fasten the fan tray with the two captive screws that were loosened in step
6. Fasten the panel that was removed in step
7. Slightly loosen the two captive screws that fasten the jumper cable guide, slide the guide
to the bottom of the rails, then tighten the screws to hold the guide in position.
191