LambdaDriver 400 & 800
ML46430, Rev. 07
October 2004
Product Specification
Parameters
Values
OUT
Port (WDM Transmit Port)
Purpose:
Connection to Mux
OUT
port, Demux
IN
port, OADM
IN
port, Service
MUX
port,
or 1+1
MUX
port
Power Attenuation (CWDM or DWDM)
Attenuation (dB)
Trunk
Width
Mux
Mux-Demux Pair
4-Channel 1.8 3.4
8-Channel 3 4.5
16-Channel 5.4 6.5
Cable Length (max):
Per the lowest power output of all the
modules in the LDx00. If a Transponder
is connected to a Mux, the cable length
depends on whether the technology is
CWDM or DWDM and on channel
bandwidth (Data Rate Range) – see
Transponder
an ESCON or GM2
is connected to a
Mux, refer to ESCON
Cable Type:
Singlemode 9/125
µ
m
Cable Connector:
SC
TX
Ports (Access Transmit Ports)
Purpose:
Connection to Transponder
WDM TX
ports, ESCON SFP
TX
ports, or GM2
TRUNK TX
ports
Power Attenuation (CWDM or DWDM)
4-Channel 1.8
dB
8-Channel 3
dB
16-Channel 5.4
dB
Cable Length (max):
1 m (~ 3 ft)
Cable Type:
Singlemode 9/125
µ
m
Cable Connectors:
MiniSC (MU)
Mounting Handle/ejector/extractor
Posidrive screws (two)
7
GM2 is 2-Gigabit-Ethernet Multiplexer module
33