7. Grip the facepiece between your thumb and fingers with both hands.
8. Insert your chin into the lower part of the facepiece.
9. Pull the facepiece headstraps over your head.
10. Smooth the straps flat against your head.
a. Support the facepiece by holding the breathing tube at the coupling nut
assembly with one hand.
b. Tighten the lower (neck) straps.
NOTE:
Pull the straps straight back, not out.
c. Tighten the side (temple) straps.
d.
For the Ultravue Facepiece:
Tighten the top (forehead) strap to position the lens for best vision and to support
the weight of the facepiece.
11. Skip section B. Refer to
4.3 Section C: Air-Tightness Test (Face-to-Facepiece Seal)
4.2
Section B: Combination Duo-Flow Type Respirators
1. Be sure that the inlet air pressure is set per the following guidelines:
Duo-Flow Valve
• High Pressure System
• Approved Air-Supply Hose Length: 8-300 ft.
• Approved inlet air pressure to maintain 4 CFM minimum to facepiece: 35-40 psig
• Dual-exhalation valve facepiece: 32-37 psig
2. Reconnect the socket assembly to the Duo-Flo valve.
3. Attach the appropriate filter to the coupling nut at the bottom of the Duo-Flo valve.
4. Connect the breathing tube to the opening at the top of the Duo-Flo tube.
5. Turn the back of the hood and collar "inside-out," exposing the facepiece headstraps.
6. Adjust the facepiece headstraps so the ends are at the buckles.
US
Abrasi-Blast Respirator
16
4 Donning