NOTICE
The P/N 476089 Filter Cartridge Holder is not approved for use with the air-purifying, Combination Duo-Flo configurations of
the Abrasi-Blast Respirator.
1. Installing the filter cartridges in the cartridge holder:
a. Unscrew the bezel ring.
b. Separate the holder valves.
WARNING!
The bottom seal (P/N: 459035) and o-ring (P/N: 637830) on the cartridge holder assembly
must be inspected after each use and monthly. If damage is present or either of the seals
are missing they must be replaced.
Failure to follow this warning can result in serious personal injury or death.
c. Screw the filter cartridge in until it is firmly seated on the gasket.
d. Separate the holder halves.
e. The bottom seal (P/N: 459035) and o-ring (P/N: 637830) on the cartridge holder assembly should be inspected
after each use and monthly. If damage is present or either of the seals are missing they must be replaced.
f. Screw the filter cartridge in until it is firmly seated on the gasket.
WARNING!
Protection voided if sealing gasket is misaligned, damaged or missing.
Failure to follow this warning can result in serious personal injury or death.
g. Place the holder halves together and tighten the bezel ring to assure a good seal at the gasket.
2. Connecting the cartridge holder (with filter cartridge installed) to the respirator:
a. Disconnect the breathing tube from the valve-connector.
b. Connect the holder's female fitting to the valve connector.
c. Be sure there is a gasket in the breathing tube coupling nut.
29
Abrasi-Blast Respirator
US
10 Accessories