USING THE COMPRESSED AIR BREATHING APPARATUS
MSA
16
AirMaXX classic
3.2.1. Pressure Reducer with Thread Connection
3.2.1.1. Preparing the Apparatus for Use with One Compressed Air Cylinder
(1) Hinge down the cylinder separator that is in the middle of the cylinder
support into a horizontal position until it catches
(2) If necessary, disconnect T-piece from high pressure socket of pressure
reducer.
Fig. 10
Compressed air breathing apparatus – details
1
Cylinder separator
3
Cylinder support
2
Cylinder retaining strap
4
Tension clamp
3.2.1.2. Connecting One Compressed Air Cylinder
(1) Place compressed air breathing apparatus horizontally so that the back face
is uppermost (
(2) Bring cylinder separator (1) into a horizontal position opposite the tension
clamp (4) until it catches.
(3) Check gasket on pressure reducer high pressure socket for proper condition.
(4) Open tension clamp on cylinder strap eliminating any tension by extending
the strap to full length pulling the small bar at the tension clamp (
Fig. 11
Opening the tension clamp