MAINTENANCE AND CARE OF THE SCBA
AirMaXX classic
27
4.2. Maintenance Intervals
Component
Work to be
Performed
Before
use
After use Annuall
y
Every 3
years
Every 9
years
1)
Compressed air
breathing
apparatus complete
Cleaning
X
X
Sight, function and
tightness check
X
X
Check by user
2)
X
Compressed air
breathing
apparatus without
cylinder and lung
governed demand
valve
Overhaul
X
alphaCLICK 2
coupling
Cleaning
X
Lubricate
X
4)
Check by user
X
Compressed air
cylinder with valve
Filling pressure
check
X
Technical expert
test
See instruction manual for compressed air
cylinder. Please observe national rules!
Lung governed
demand valve
See instruction manuals for lung governed demand valve / full face mask.
Please observe national regulations!
3)
1)
For SCBA apparatus that are frequently used, we recommend a complete overhaul after
approx. 540 hours. For example, this corresponds to 1080 applications with a duration of 30 minutes.
2)
The checks are performed with the respective lung governed demand valves and if required, with the
respective full masks.
3)
Rubber components are subject to ageing with varying rates according to local conditions and must be
checked and replaced at regular intervals.
4)
Lubricate
alphaCLICK 2
coupling every 500 coupling cycles at least (see maintenance manual).
4.3. Cleaning
4.3.1. Pre-cleaning
(1) Open cylinder valve(s) of the mounted compressed air cylinder(s) fully.
(2) Remove rough dirt from breathing apparatus with water hose. Here, we
recommend using a mild detergent.
(3) Close cylinder valve(s), release air from apparatus with lung governed
demand valve.
4.3.2. Cleaning, light Soiling
(1) Remove compressed air cylinder(s) (
Section 3.11).
(2) Clean compressed air breathing apparatus manually using a brush, damp
cloth or similar.
(3) Dry apparatus completely in a drying cabinet at max. 60°C.