Monitoring Combustible Gases
The device can monitor these concentrations in ambient air:
•
Methane
•
Combustible gases
The device displays the combustible gas concentration in % LEL or % CH
4
on the Measuring page until
another page is selected or the device is turned off.
WARNING!
If an alarm activates while using the device, leave the area immediately.
Remaining in the area under such circumstances can cause serious personal injury or death.
The device has two alarm set points:
•
HIGH Alarm
•
LOW Alarm
If the gas concentration reaches or exceeds the alarm set point, the device:
•
backlight turns on
•
a vibrating alarm triggers
•
displays and flashes the Alarm symbol and either the Minimum icon (LOW alarm) or the Maximum
(PEAK) icon (HIGH alarm)
•
enters an alarm state.
WARNING!
A combustible gas reading of “100” or “5” indicates the atmosphere is above 100% LEL or 5.00% vol
CH
4
respectively, and an explosion hazard exists. Move away from contaminated area immediately.
In such cases, the device enters a Lock Alarm state.
When a gas reading reaches 100% LEL or 5.00% CH
4
, the device enters a Lock Alarm
state: the combustible sensor shuts down and displays “XXX” in place of the actual
reading. This state can only be reset by turning the device off and on in a fresh air envi-
ronment.
When a gas reading falls below a defined under-range threshold, the device displays " -
- -" in place of the actual reading.
Check your national standard values for 100 % LEL (EN60079-20-1).
Summary of Contents for ALTAIR 4XR
Page 1: ...MSAsafety com Operating Manual ALTAIR 4XR Multigas Detector Order No 10175896 00 ...
Page 52: ...ALTAIR 4XR 52 Appendix US 7 Appendix 7 1 Start Up Sequence Power on ...
Page 53: ...ALTAIR 4XR 53 Appendix US 7 2 Fresh Air Setup FAS ...
Page 55: ...ALTAIR 4XR 55 Appendix US ...
Page 56: ...ALTAIR 4XR 56 Appendix US 7 4 Bump Test ...
Page 57: ...ALTAIR 4XR 57 Appendix US 7 5 Options Setup ...
Page 58: ...ALTAIR 4XR 58 Appendix US 7 6 Sensor Setup ...
Page 59: ...ALTAIR 4XR 59 Appendix US 7 7 Calibrations ...
Page 60: ...ALTAIR 4XR 60 Appendix US ...
Page 61: ...ALTAIR 4XR 61 Appendix US 7 8 Alarm Setup ...
Page 62: ...ALTAIR 4XR 62 Appendix US 7 9 Time and Date Setup ...
Page 63: ...sales norrscope com ALTAIR 4XR 63 Appendix US 7 10 Bluetooth Setup ...