ALTAIR
®
4XR
48
Technical Data
US
(7)
The conversion factors for the standard EX and the specialized EX-H and
EX-M sensor are the same except for EX-H and Nonane and o-Xylene. The conversion factors
for these two vapors are therefore especially mentioned in the table.
Oxygen
The oxygen sensor has built-in temperature compensation. However, if temperature shifts dramatically,
the oxygen sensor reading may shift. Zero the device at a temperature within 30 °C (86 °F) of the work
place temperature for the least effect.
* Certified for 0 - 25 vol.% O
2
Carbon Monoxide
Range
0 to 30 vol.% O
2
*
Resolution
0.1 vol.% O
2
Reproducibility
0.7 vol.% O
2
for 0 to 30 vol.% O
2
Response time
(90% of final reading)
<10 second (normal temperature range)
Sensor Cross-Sensitivity
The oxygen sensor has no common cross-sensitivities.
Data is presented as the indicated output in PPM which will result from the application
of the test gas.
Range
0 - 1999 ppm (0 - 1999 mg/m
3
) CO
Resolution
1 ppm (1.2 mg/m
3
) CO for 0 to 1999 ppm
Reproducibility
±5 ppm (5.8 mg/m
3
) CO or 10 % of reading,
whichever is greater
(normal temperature range)
±10 ppm (11.6 mg/m
3
) CO or 20 % of reading,
whichever is greater
Response time
90% of final reading in less than or equal to 15 seconds
(normal temperature range)
Test Gas Applied
Concentration (PPM) Applied
CO Channel %
Cross-sensitivity
Hydrogen Sulfide (H
2
S)
40
0
Carbon Monoxide (CO)
100
100
Nitric Oxide (NO)
50
84
Nitrogen Dioxide (NO
2
)
11
0
Sulfur Dioxide (SO
2
)
9
-4
Chlorine (Cl
2
)
10
0
Hydrogen Cyanide (HCN)
30
-5
Ammonia (NH
3
)
25
0
Toluene 53
0
Summary of Contents for ALTAIR 4XR
Page 1: ...MSAsafety com Operating Manual ALTAIR 4XR Multigas Detector Order No 10175896 00 ...
Page 52: ...ALTAIR 4XR 52 Appendix US 7 Appendix 7 1 Start Up Sequence Power on ...
Page 53: ...ALTAIR 4XR 53 Appendix US 7 2 Fresh Air Setup FAS ...
Page 55: ...ALTAIR 4XR 55 Appendix US ...
Page 56: ...ALTAIR 4XR 56 Appendix US 7 4 Bump Test ...
Page 57: ...ALTAIR 4XR 57 Appendix US 7 5 Options Setup ...
Page 58: ...ALTAIR 4XR 58 Appendix US 7 6 Sensor Setup ...
Page 59: ...ALTAIR 4XR 59 Appendix US 7 7 Calibrations ...
Page 60: ...ALTAIR 4XR 60 Appendix US ...
Page 61: ...ALTAIR 4XR 61 Appendix US 7 8 Alarm Setup ...
Page 62: ...ALTAIR 4XR 62 Appendix US 7 9 Time and Date Setup ...
Page 63: ...sales norrscope com ALTAIR 4XR 63 Appendix US 7 10 Bluetooth Setup ...